Timer relay module

The 859 Series DIN-rail Timer Relay Module from Wago has On-/Off-Delay timer modes and multiple time ranges for switch and package de-bounce sensors.

12/09/2011


The 859 Series DIN-rail Timer Relay Module has On-/Off-Delay timer modes and multiple time ranges for switch and package de-bounce sensors. Courtesy: WAGOWago Corp.’s 859 Series DIN-rail Timer Relay Module offers On-/Off-Delay timer modes and multiple time ranges for diverse applications such as switch and package “de-bounce” sensors. Unlike traditional designs, the 6 mm 859 Series carries a top-mounted potentiometer for fine-tuning delay time without removing unit from DIN-rail. On-Delay mode can prevent simultaneous excess inrush currents by delaying machine startup. Off-Delay mode can enable auxiliary components, such as fans, to continue operation after machine shutdown.

The 859 Series is available with Electromechanical (SPDT) or Solid State Relay (SPST-N.O.) outputs. Selectable via two DIP switches, 859 Series provides four standard time delay ranges from 0.2 seconds to 10 minutes. Optional time delay ranges of 2.0 seconds to 35 minutes are also available. 859 Series input voltage ranges from 19.2–28.8 V dc; outputs are 6A/24 V dc (electromechanical) and 2A/24 V dc (Solid State).

www.wago.us

Wago Corporation

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me