The challenges of maintenance planning

7 tips to get the most out of your process and people

01/26/2012


Excerpted from SMGlobal’s Maintenance Software Blog

Planning maintenance work can be a challenge because it normally consists of two different types of maintenance:

  • Unplanned or emergency maintenance to fix equipment breakdowns or other urgent work as it comes up
  • Planned or preventative maintenance to keep systems/equipment running in peak condition

How does one consolidate and manage these two types of jobs? How can one allocate maintenance technicians and work hours in the daily calendar to get both types of work accomplished? Many maintenance programs have grown organically over the years and end up mainly doing breakdown/ unplanned maintenance. Technicians work in fire fighting mode and preventative planned maintenance typically takes a hit. Not doing preventative maintenance on time (or not at all!) results in further unexpected equipment breakdowns and further emergency maintenance work.

Maintenance Planning Tips

  1. Since unplanned/ breakdown maintenance by its very nature is unpredictable, try to build in buffer time to handle such work. Break each day or week into periods for planned maintenance based on category A (must be done), B (should be done sometime soon) and C (nice to do). Unplanned maintenance can be scheduled as needed around time for category C or even category B maintenance. This can help prevent cascading maintenance issues and associated continuous firefighting.
  2. Make sure to allot enough time and resources for regular preventative maintenance in the maintenance plan
  3. The operating principle when handling any large multi-day, multi-team maintenance job should be “divide and conquer”. Break the whole job down into separate tasks that can be done by different teams or personnel. Here a good CMMS program can help you split the job into separate tasks and “chain” them together so that each sub-task is completed when the prior one is done
  4. Get a good maintenance management software product (CMMS software) that will help you manage both unplanned as well as planned maintenance in a single interface.
  5. Remember that estimates should be based on the person who will be doing the job not on the experience of someone who may be an expert at this job. Inexperienced personnel will take more time to complete many jobs. Having unrealistic estimates will cause backlog and can completely ruin an otherwise well thought out maintenance plan.
  6. When making maintenance plans build in time for recording, updating & reviewing information. Otherwise these elements will be the first to be skipped.
  7. Put together a maintenance calendar of work to be done in the next month, quarter or year by equipment/ and location. This can be useful to show & discuss with production/ operations managers. Items may need to be rescheduled or grouped together to reduce the time equipment is unavailable due to maintenance work or identify conflicts due to production/ operations deadlines. This is another area where a good CMMS/ maintenance software can help since it makes it easier to reschedule and move around jobs.

 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.