Tees and splitters for CAN networks, mobile equipment

Minifast splitters and tees by Turck provide voltage monitoring for DeviceNet applications and contain an integrated circuit board as a diagonstic tool.

09/26/2012


Minifast splitters and tees by Turck provide voltage monitoring for DeviceNet applications and contain an integrated circuit board as a diagonstic tool. Courtesy: TurckTurck's 7/8-16UN minifast tees, splitters and in-line diagnostic devices are designed for use in DeviceNet applications, including CAN networks and mobile equipment. Models are available in a standard option for classic DeviceNet use and a voltage monitoring version that contains an integrated circuit board to serve as a diagnostic tool. Voltage monitoring tees and splitters help troubleshoot and prevent downtime with LEDs that report normal, over-voltage and under-voltage conditions. 

The splitters provide parallel wiring, which simplifies installations. The ‘h’ configuration contains a tee connected to the main trunk line with one premolded cable drop, providing a quick, convenient and space-saving way to add additional cabling within the cable tray. The splitters may be specified with any gender; negating the traditional male to female connection requirement. Additionally, the in-line diagnostic devices may be used as gender changers to connect a male to male or female to female cordset.

Designed to accommodate diverse conditions, the minifast splitters and tees can handle up to 30 volts in temperatures ranging from -40 to 105 degrees C. The splitters and tees also feature an IP67 environmental protection rating, providing an ideal solution for voltage trouble spots in harsh conditions.

Turck

www.turck.us 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.