Statue of Liberty rescue elevator project information

The Statue of Liberty rescue elevator project, part of a $30 million renovation, included the following project participants and product components.

03/18/2013


For emergency personnel and maintenance activity only, the Statue of Liberty rescue elevator is the only elevator inside the statue, traveling from the top of the pedestal to the crown. It was custom designed specifically for this application and locationAn integral component of the Statue of Liberty rescue elevator is a 25 hp ABB ACS800 Variable Frequency Drive (drive), featuring ABB Direct Torque Control (DTC), a patented motor control technology. The drive controls the two 10 hp SEW-Eurodrive motors that move the elevator, and collaborates with a Siemens Safety PLC in controlling the overall elevator system. (See related application article, linked below with more photos.)

“The ABB Drive is the heart and soul of the drive system,” said Brian Trapani, the lead project engineer for TESI on the project. “It controls the two motors simultaneously and makes sure the elevator rides smoothly.”

“The ABB ACS800 is a very advanced drive. It can run with open-loop control with no issues, and the control structure is very tight,” said Trapani.

Todd Grovatt, TESI president, said, “We switched to ABB a few years ago because they have advanced technology that other drives don’t feature. We now have four or five systems in place with ACS800s. It is a real workhorse.”

Project participants

  • Customer – National Park Service for the Statue of Liberty
  • General Contractor - Joseph A. Natoli Construction Corporation; Pine Brook, N.J.
  • Vertical Transportation Sub-contract -  Liberty Elevator Corporation; Patterson, N.J
  • Rescue Elevator: Design and Manufacture - Tower Elevator Systems Inc. (TESI); Austin, Texas

Rescue elevator specifications

  • Goes from the top of the pedestal (6p) to four elevated landings (4s, 5s, 6s, 7s); 12 to 20 ft apart along the 80 ft rise
  • 2 ft wide x 3.5 ft long platform
  • 150 ft/min. speed
  • Capacity: 3 people, with a fold-out seat

Drive, motors, programmable logic controller (PLC)

- One ABB ACS 800, 25 hp drive, a variable frequency drive (VFD)

- Two 10 hp SEW-Eurodrive gear motors

- One Siemens Simatic ET200S Safety PLC

- Information provided by ABB and Tower Elevator Systems; edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske(at)cfemedia.com.

Motion control: Statue of Liberty rescue elevator

www.abb.us/drives 

www.nps.gov/stli 

www.seweurodrive.com 

http://usa.siemens.com/automation 

www.statueofliberty.org 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.