SEARCH Archives
Loading
Sponsored by:

Sensor for guiding robotic vehicles

The MGS1600 by Roboteq is a magnetic guide sensor that uses signal processing to measure lateral distance with millimeter resolution and can detect and manage up to 2-way forks.

01/10/2013


The MGS1600 by Roboteq is a magnetic guide sensor that uses signal processing to measure lateral distance with millimeter resolution and can detect and manage up to 2-way forks. Courtesy: RoboteqRoboteq Inc. introduces a magnetic guide sensor capable of detecting and reporting the position of a magnetic field along its horizontal axis. The sensor is intended for line following robotic applications, using adhesive magnetictape to form a track guide on the floor. The 160 mm wide sensor uses advanced signal processing to accurately measure its lateral distance from the center of the track, from a height up to 60 mm and a position resolution of 1 mm. The sensor is primarily used to steer Automatic Guided Vehicles (AGVs), moving material on factory floors.

The MGS1600 tape position information can be output in numerical format on the sensor's RS232, USB, CANbus, Analog or PWM ports. The sensor can also be connected to any PLC using a choice of Analog, PWM, RS232 or CANbus interfaces. Using USB, the sensor can easily be interfaced to any PC compatible computer.

The sensor will detect and manage up to 2-way forks and can be instructed to follow the left or right track using commands issued via its digital inputs, the Serial, USB or CANbus ports. In addition to detecting a magnetic guide track to follow, the sensor will detect and report the presence of magnetic markers that may be positioned on the left or right side of the track. Markers are made of the same magnetic tape but of opposite polarity. The sensor is equipped with several LEDs for easy monitoring and diagnostics. The sensor incorporates a high performance, basic scripting language that allows users to add fully customized functionality to the sensor.

The sensor is delivered with a powerful PC utility for configuring its settings, and updating its firmware in the field with new features as they become available.

To help with system setup and troubleshooting, the utility also includes as a strip chart recorder, and a visualization window to display in realtime, the magnetic field as it is seen by the sensor.

Roboteq Inc.

www.roboteq.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.