Profinet modules added to automation product range
The LioN-M IO Profinet module by Belden has been added to the Lumberg Automation product range. The modules support real time (RT) and isochronous real time (IRT) standards.
Belden Inc. has added LioN-M I/O Profinet modules to its Lumberg Automation product range. The Profinet I/O modules support both real time (RT) and isochronous real time (IRT) standards.
In the 0980 ESL 701 (16DI) module, channels are used as inputs, and in the universal version 0980 ESL 700 (16DIO Universal) they are used as either inputs or outputs in any combination up to a total of 16 points. The 0980 ESL 700 has a rated output current of up to 1.6A, with a maximum total current capacity of 9A. The diagnostic concept enables precise fault location for each individual port. Both modules facilitate line topologies and can also be used for existing communications structures such as cable ducts and energy chains without making any changes to their physical layout. The universal module offers flexibility not only at the planning stage, but also when making changes at the commissioning stage or during subsequent upgrades.
Both network ports are equipped with four-pole M12 connectors with D coding. The eight I/O ports, each of which can be assigned to two digital I/O signals, have five-pole M12 connectors with A coding. The network ports are color-coded to prevent any possible confusion. These Profinet IO modules support DCP and LLDP. DCP protocol is used to assign the unique Profinet device name to the module. By this device name the module is clearly identified in the Profinet network.
The I/O modules have a robust housing made of PBT (polybutylene terephthalate) and measures 243 x 60 x 23 mm. Both versions meet the requirements for industrial protection class IP67 and are designed for temperatures ranging from 10 C to +60 C. The power supply, which is connected via two five-pole 7/8 in. connectors, has a rated voltage of 24 V and a range of 11 V to 30 V.
Belden Inc.
- Edited by Chris Vavra, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.