Product Exclusive: Smart redundancy modules have auto current balancing technology

Phoenix Contact Quint Oring active redundancy modules use new auto current balancing (ACB) technology for precise load sharing, plus load current monitoring, remote diagnostics, and visual indications, for reliable, redundant power systems.

09/23/2011


Phoenix Contact’s Quint Oring active redundancy modules use new auto current balancing (ACB) technology for precise load sharing. The ACB technology, coupled with load current monitoring, remote diagnostics, and visual indications, ensures maximum reliability in redundant power systems. ACB automatically and symmetrically distributes the load current without regard to effects such as temperature drift. With a balanced current draw, lifetime expectancy of each power supply may double. The Quint Oring module’s display shows the status of the load sharing. If the module nears a critical state, it will generate an alarm.

Phoenix Contact Quint Oring. Photo courtesy: Phoenix Contact

In addition to the ACB, the Quint Oring module can monitor the load current. If a load powered by redundant power supplies draws more current than one power supply can provide, this essentially defeats the redundancy. At this point the Quint Oring will send an alarm to the control system. Typically this functionality would require an additional current monitoring product.

Phoenix Contact Quint Oring LED. Photo courtesy: Phoenix ContactThe Quint Oring can also diagnose itself. If the internal redundancy is defeated, the module generates an alarm to the control system.

Quint Oring technology uses metal-oxide semiconductor field-effect transistors (MOSFETs) for decoupling instead of the typical Schottky or silicon diode.  This saves up to 70% more energy than traditional modules and reduces heat in a control cabinet.

The Quint Oring is available in two 24 V dc versions. The 32-mm-wide module accepts up to two 5- or 10-amp inputs. A 38-mm-wide version accepts up to two 10- or 20-amp inputs.

www.phoenixcontact.com/redundancy

Phoenix Contact

Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect, and automate systems and equipment for a wide range of industries. Phoenix Contact GmbH and Co. KG, Blomberg, Germany, operates 47 international subsidiaries, including Phoenix Contact USA in Middletown, Pa.

Control Engineering webcasts include information on Ethernet optimization.

www.controleng.com/media-library/webcasts.html



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.