Product Exclusive: Large, color PLC+HMI touchscreen

Unitronics new Vision1210 is an industrial programmable logic controller integrated with a 12.1-in. color human-machine interface with touchscreen.

06/22/2011


Unitronics' Vision1210 is fully programmable logic controller with a 12.1-in. color touchscreen.Unitronics introduces the newest big-screen member of its PLC+HMI family, the Unitronics Vision1210. Industrial control processes can now enjoy full programmable logic controller (PLC) functionality with a larger-than-ever 12.1-in., 65,000-color touchscreen. Integrating a PLC and HMI gives users an opportunity to operate on a minimum of budget, programming time, and wiring, the company said.

With an IP66 rating, the controller is well suited for the food industry, wherever spray or wipe down applications apply. A wide variety of onboard I/O options can be added by snapping a module onto the back of the PLC. Expandable up to 1,024 I/O, these configurations include digital and analog inputs and outputs, high-speed I/O, PT100/thermocouple capabilities, and weight measurement. They can be mounted locally or remotely, up to 1000 m from the controller. This power-PLC is equipped with a built-in USB programming port, recipe capabilities, Micro SD card memory storage for data logging and backup, complete PLC cloning, and more.

Systems integrators can now rely on one device: The Vision1210 can support 24 auto-tuned PID loops to control temperature, level, and pressure, while the 16-bit SVGA color touchscreen displays data, color trend graphs, and attention-grabbing alarm screens. Display options are almost endless, with more than 1,000 user-designed screens, and up to 500 images per application. Internal memory holds 2 MB of application logic, plus 1 MB for fonts and 32 MB for images.

Communication options include TCP/IP Ethernet, cellular, and industrial protocols, such as Modbus, DF1 slave, J1939, CANopen, and others. In addition, the controller can be “taught” to communicate via almost any device-based protocol. It also is capable of time-based and immediate interrupts, making it a natural for rapid-response applications, such as packaging machines.

Unitronics’ free VisiLogic software provides one user-friendly environment for hardware configuration, modular Ladder application development, and HMI design, including a rich color library of industrial images, the company said. Unitronics also offers free technical support for all products.

Vision1210 reduces overall system costs by minimizing hardware requirements, saving cabinet space, and—above all—exempting the user from setting up panel-PLC communication.

www.unitronics.com Unitronics



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.