Pluggable connector system

The picoMAX by Wago Corporation uses a dual-purpose spring design for strong integrity and connection strength and is available in 2-12 pole configuration for a variety of panel feedthrough variants.

02/25/2013


The picoMAX by Wago Corporation uses a dual-purpose spring design for strong integrity and connection strength and is available in 2-12 pole configuration for a variety of panel feedthrough variants. Courtesy: WagoA shortened current path, minimal voltage drop and vibration-resistance up to 20 g enable WAGO Corporation's picoMAX to change the price-to-performance ratio for PCB applications. The Pluggable Connection System employs a dual-purpose spring design that applies the force of one contact spring for strong integrity and connection strength. This results in up to 30% space reduction for wire-to-board applications, segment-leading vibration-resistance and absolute connection integrity in operating temperatures up to 125°C.

picoMAX is based on a patented male header and female connector design. The dynamic contact force from one Cr-Ni stainless steel spring clamps conductors and connects the header pin. A truncated contact bridge separates the termination unit from header pin, minimizing contact resistance for absolute signal integrity. Applications: industrial electronics such as panel meters, controllers, data loggers and consumer electronics, e.g., garage door openers.

Terminations are simple: directly insert solid or ferruled conductors. Integrated push-buttons provide terminations for strandedconductors. Select units carry gripping plates with Sliding connector release. An unlocking tool is available for units without gripping plates.

picoMAX is available in 2-12 pole configurations for wire-to-wire, wire-to-board, board-to-wire and panel feedthrough variants. It accommodates conductors 24-12 AWG and carries ratings up to 15 A/300 V. 3.5 mm, 5 mm or 7.5 mm pin spacing are available.

Wago Corporation

www.wago.us 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me