SEARCH Archives
Loading
Sponsored by:

Over the air programming with 802.15.4, ZigBee

New OTA technology from Libelium allows a network to be re-programmed in a couple of minutes by using multihop routing.

06/20/2011


Libelium, a technology company specializing in wireless sensor networks, has announced the launch of Libelium OTA, a solution that lays the foundation for over the air programming (OTAP) for wireless sensor networks and the Internet of Things. This brings OTA capabilities for the first time to unlicensed frequency bands (2.4 GHz, 868 MHz, 900 MHz) and to low power communication using protocols such as 802.15.4 and ZigBee.

Over the last decade wireless programming or over the air provisioning (OTA) has been widely used by the mobile phone industry. This capability has allowed software updates to be delivered to mobile phone users and to enable the deployment of new services as they become available. So far, such capabilities have not been available to wireless sensor networks or to the Internet of Things. Such networks, usually consisting of hundreds or thousands of nodes (“motes”), would benefit from an OTA capability.

David Gascón, Libelium’s CTO, said “Motes are often located in places that are either remote or difficult to access. Libelium OTA will enable firmware upgrades to be made over a wireless network without the need of physical access.” He added, “The new OTAP feature, together with battery recharging via a solar panel, will keep the maintenance costs of wireless sensor networks to a minimum allowing the deployment of networks with thousands of nodes.”

Firmware upgrades can be made within minutes and it is possible to choose between updating single nodes (unicast), multiple nodes (multicast) or an entire network (broadcast). OTA can also be used for the recovery of stuck nodes. Furthermore it is possible to find nodes in a particular area by broadcasting a discovery query.

Libelium OTA can work with both direct-access and multihop-access. In the case of 802.15.4 networks, the nodes to be upgraded can be accessed directly by the gateway. With ZigBee, it is usual that a series of nodes must forward packets sent by the gateway to the chosen destination. When performing OTA with direct access the frequency channel used in the 2.4GHz band is changed so no interferences are caused to the rest of the nodes.

The Libelium OTA provides two levels of security: firstly the data transmitted is encrypted using the AES-128 algorithm; secondly a pass key must be authenticated in each node before the OTA process starts.

For wireless sensor networks implemented with Waspmote, programs sent are stored in a 2GB SD card enabling thousands of software versions to be stored and managed on a single mote. The management OTA application runs in Windows, MacOS and Linux and it is freely available for clients of the Waspmote platform.

Libelium is launching a special training course at their headquarters in Zaragoza, Spain, in June for those interested in learning the OTA capabilities quickly.

The first public demonstration of Libelium OTA was June 6-8, 2011, booth #500 at the Sensors Expo & Conference in Rosemont, IL.

www.libelium.com/ota

Libelium Comunicaciones Distribuidas S.L.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.