Multistage, enclosed surge protection devices

The OVR NE12 is an enclosed surge protection device (SPD) designed to protect valuable equipment connected to the network for critical power, renewable energy, water, and other commercial applications.

12/10/2011


The OVR NE12 is an enclosed surge protection device (SPD) designed to protect valuable equipment connected to the network for critical power, renewable energy, water, and other commercial applications. Courtesy: ABBThe ABB Low Voltage Products division has released the OVR NE12 enclosed surge protective device (SPD), designed for a long service life protecting valuable equipment from damage caused by transient surges from lightning strikes, and surges from upstream equipment and utility load switching. The OVR NE 12 is a multistage protector with fast acting metal oxide varistors (MOV) and an EMI/RFI noise attenuation filter to limit overvoltage to values compatible with the sensitive equipment connected to the network. Extensive damage and expensive repairs can result from transient surges if surge protection is not present. The OVR NE12 is ideal for critical power facilities such as hospitals and data centers, renewable energy installations, water and wastewater systems, and other surge-sensitive manufacturing and commercial operations.

The OVR NE12 is a UL 1449 3rd Edition certified Type 2 SPD contained within a NEMA Type 12 enclosure, designed for installation indoors on the load side of the main breaker or fuse. The new SDP uses MOV technology to achieve a high level of protection performance, and allows for ease of module replacement. Each OVR NE12 comes standard with status lights, alarm, auxiliary contacts, EMI filtering and a fused disconnect. An additional benefit is an optional surge counter/diagnostic LCD display that records the date and time of surges 2kA and above, in addition to providing enhanced information on unit status.

The OVR NE12 is available in three service voltage versions - 240/120 V ac Split Phase, 480 V ac Delta, and 480Y/277 V ac; and two protection levels - 160 and 320 kA per phase (Imax). It is optimally used in addition to ABB OVR DIN rail SPDs at branch panels and equipment, creating a multi-level apĀ­proach to protection.

www.abb.com

The ABB Group

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.