Multiple hop radios have I/O connections

Banner Engineering's Surecross MultiHop radios are designed for remote applications and can connect to control systems to communicate with input/output devices.

08/30/2011


Banner Engineering Corp. introduces new SureCross MultiHop radios with I/O to its line of industrial wireless products. SureCross MultiHop radios connect to existing plant-wide control systems to communicate with input and output devices. The MultiHop radios are a designed for remote applications such as lift station control, large-scale irrigation automation, detention pond management and other areas where line of sight is not possible due to difficult terrain.

"MultiHop Radios with I/O are designed to easily extend the range of an existing wired network and to expand the reach of process control without the need for lengthy cable runs," said Chris Dales, wireless sales manager at Banner Engineering. "It is also important to note that our MultiHop radios are not limited to areas where only wired power is available. Even with alternative power sources, the radios still maintain all the wireless communication reliability inherent to the SureCross family."

Banner's SureCross MultiHop wireless sensor networks typically consist of one master radio, but may include many repeater and slave radios. The operational modes are selected by the customer via integrated DIP switches, simplifying the specification process. MultiHop radios automatically form self-healing, auto-routing radio networks with multiple hops to extend the range of a Modbus or other serial communication network. In the event a communication pathway becomes unavailable, the radios will find a route back to the network master without operator intervention. Additional integrated network addressing reduces interference from collocated networks, and the built-in site survey capability enables rapid assessment of a location’s transmission properties.

SureCross MultiHop radios transmit at 1 watt with license-free operation in the Industrial Scientific and Medical (ISM) band—no monthly data plan or annual fees are required. With a high-gain antenna, a range of over 6 miles per hop can be achieved. All I/O communication is performed on a Modbus platform and can be easily integrated with existing PLCs, HMIs or other plant-wide systems. MultiHop radios are available in the 2.4 GHz bandwidth to meet worldwide radio compliance restrictions.

www.bannerengineering.com 

Banner Engineering Corp.

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

Wireless articles and tutorials are available at www.controleng.com/wireless.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me