Motor series for compact and higher performing machines

Kollmorgen’s AKM 8 Servomotors allow OEMs to specify the exact servomotor solution with superior performance, reduced time to market, competitive pricing.

02/28/2011


Kollmorgen Motor SeriesKollmorgen introduces AKM 8 Servomotors - the addition to the company’s AKM motor series. With a feature-set to satisfy global requirements, AKM8 motors allegedly deliver higher torque density to cover the broadest torque/speed range in a housing that is 30% shorter than any standard motor in its class available today. As a result machine builders can reduce the size of their machines without sacrificing performance or they can select a longer stack length to achieve higher performance without having to specify a larger motor that would typically require mechanical changes to the machine.

“The AKM high performance motor series offers a wide range of mounting, connectivity, feedback and other options and, with the addition of the AKM8, is now available in 8 frame sizes, 28 frame/stack combinations and 112 ‘standard’ windings. The result is unprecedented choice and flexibility to satisfy the exact needs of even more global applications, with the favorable delivery times and lower cost of a standard product. This is particularly significant for today’s machine builders who need to get a better, globally-deployable, machine to market, faster,” says Gene Matthews, Product Manager.

The AKM8 is available in two standard flange/shaft combinations reportedly designed to integrate with 80% - 90% of machine builder needs around the globe, with no modifications to the customer flange needed. As standard, AKM8 windings are designed to operate at 230, 400, 480 VAC, allegedly eliminating the need for voltage transformation for machines that will be deployed in various geographic regions. AKM8 motors feature Class F insulation for a temperature rating of 155°C, and provide stall torque from 75 to 180 Nm, operating speeds up to 2500 rpm, and power up to 19.8 KW, with bearing lifetime rated to 20,000 h. These motors are RoHS and REACH compliant, UL listed, and carry the CE mark.

All AKM series motors feature a one-piece housing with potted windings purportedly for maximum wire isolation and excellent heat dissipation. Market-standard high resolution feedback options for high- performance/precision or rugged environments are available, including Endat, BISS, Hiperface, and resolver option, among others. AKM motors are available for low or high speed (to 8000 rpm) applications, with windings that can be applied to all standard global voltages including 75 VDC, 120, 240, 400 and 480 VAC. A number of options are available to satisfy wide ranging application needs including a reinforced bearing to handle higher radial force, a sealing option to achieve IP67 protection at the flange, as well as varied connectivity and mounting options.

For truly unique applications where the standard AKM offerings don’t meet the requirements of a given application, the Kollmorgen engineering support team can work alongside OEMs to customize a solution to satisfy their needs.

www.kollmorgen.com

Kollmorgen

- Edited by Gust Gianos, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me