SEARCH Archives
Loading
Sponsored by:

Miniature extended range proximity sensors

X-Series Pile Driver Extended Range Inductive Series by Pepperl+Fuchs are now available in 8 mm diameter models that can be used in metal-forming and welding applications.

01/23/2012


X-Series Pile Driver Extended Range Inductive Series by Pepperl+Fuchs are now available in 8mm diameter models that can be used in metalforming and welding applications that require precision and accuracy. Courtesy: Pepperl+FuchsPepperl+Fuchs X-Series Pile Driver Extended Range Inductive Sensors are now available in 8 mm diameter models. With barrel lengths as short as 35 mm, these miniature sensors deliver a 3 mm sensing range – 50% more range than is available from larger competitive 12 mm diameter models. As a result, 8 mm diameter extended range Pile Driver sensors eliminate the need to sacrifice sensing range or durability. Like all Pile Driver sensors, its robust, single-piece machined barrel is fully embeddable in steel making it an ideal sensing solution for the toughest metalforming and welding applications.

100% stainless steel housings deliver durability and Black Armor coated weld-immune models are available to repel even the hottest slag particles. Pig-tail connect versions feature integral high visibility power supply and target presence LEDs. X-Series Pile Driver extended range sensors are also available in 12 mm, 18 mm, and 30 mm diameters to deliver sensing ranges of 5 mm, 10 mm or 15 mm – up to 2.5 times longer range than traditional inductive sensors.

X-Series Pile Driver’s extended sensing field is useful in automotive manufacturing applications, as it enables reliable detection of irregularly shaped contours, and increased sensor-to-target distances help eliminate contact-related scuffing of “Class A” hood, door and trunk surfaces. Weld-immune models are uniquely capable of providing long range part detection with full immunity to both ac and dc weld fields, and repelling weld splatter.

X-Series Pile Driver’s can detect all metals. Advanced circuitry enables restriction-free mounting while delivering the highest available immunity to the effects of industrial noise and temperature extremes. X-Series Pile Driver sensors are IP69k-rated to withstand high pressure washdown cleaning.

Pepperl+Fuchs

www.pepperl-fuchs.us

- Edited by Chris Vavra, Control Engineering, www.controleng.com

controleng.com/sensors



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.