Machine vision system inspects, reads barcodes

Cognex ISE 4.5, an inspection tool, is designed to have multiple functions, such as being able to read barcodes and provide inspections simultaneously.

10/01/2011


Cognex In-Sight Explorer 4.5 expands the capabilities of In-Sight vision systems and gives In-Sight the most advanced inspection tools available, the company said. In-Sight Explorer 4.5 inspection tools include an all-in-one edge and surface inspection tool, an all-in-one bead width and position tool, and a robust ID tool that reads multiple codes at one time, allowing In-Sight cameras to read barcodes and provide inspections simultaneously. 

The new Flexible Flaw Detection (FFD) edge and surface inspection tool works for both color and grayscale applications and is used to inspect for boundary defects, such as conformity of shape, and surface defects like stains and scratches. FFD can also be used for print inspections, like inspecting screened logos for defects. FFD also gives users the flexibility to select accuracy versus speed requirements and the ability to ignore defects during system run time.

"Normal process variation causes false rejects without flex tools," said Bhaskar Banerjee, Business Unit Manager for Cognex Vision Systems. "Our new Flex Flaw Detection tool provides a more accurate inspection that overcomes errors from lens and perspective distortion, scale changes, print registration errors, and stretch from line scan images in one easy tool."

In-Sight Explorer 4.5 also reportedly includes two new EasyBuilder user interface tools, Bead Finder and Bead Tracker. Bead Finder and Bead Tracker are easy-to-use tools that find positional defects and width-based defects and gaps, and also provide all bead data needed for process control.

ReadIDMax was also added to In-Sight Explorer 4.5. ReadIDMax is based on the powerful and field-proven ID algorithms 1DMax and 2DMax for 1-D barcode and 2-D matrix code reading. ReadIDMax adds the ability to read up to 128 codes at one time regardless of the position of the code in the field-of-view. Now, end users can read multiple codes and inspect parts simultaneously.

In-Sight Explorer 4.5 also includes communication enhancements that include support for CIP-Sync, a precision clock synchronization protocol and UDP communication. In-Sight Explorer 4.5 also reportedly supports sending camera control commands from Mitsubishi PLC using MC-protocol.

In-Sight smart cameras are designed mainly for automated inspection and quality assurance across a wide range of industries. In-Sight vision systems can reportedly be integrated with any factory network or automation control system and feature an optional operator display panel for monitoring the runtime operation of any In-Sight vision system on the network.

www.cognex.com

Cognex Corporation

Machine vision tutorials, case studies



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me