Machine vision: high-speed, long-distance communications

CoaXPress (CXP) is a high-speed point-to-point serial communication standard for the transmission of video data, scalable over single or multiple coaxial cables. It has a high-speed downlink of up to 6.25Gb/S per cable for video, images, and data, plus a lower speed, 20Mb/S uplink for communications and control.

Donal Waide

06/04/2012


BitFlow, a manufacturer of high-speed frame grabbers since 1993, recently introduced its latest CoaXPress frame grabber, the Karbon-CXP4.Broken down to its simplest terms, machine vision is the ability to use a camera, computer, and an illumination source to make a decision. Each component—camera, computer, and illuminator—has witnessed rapid changes over the past decade, transforming the imaging landscape and making machine vision more powerful, scalable, and affordable.

While we are all well aware of the seemingly daily developments in PC architecture and the migration from analog to digital cameras, there is a less frequently mentioned component to machine vision: the interface technologies between the camera and the computer. 

Cameras need to transmit data to the computer so that it arrives intact in a relatively short time frame. When analog cameras were in fashion, and some of them still are, this interface was a BNC coaxial connection between the camera and a data acquisition board known as a frame grabber. The frame grabber was usually a PCI interface that fit into the motherboard that allowed data to transfer seamlessly between camera and computer memory.

Just as cameras, computers, and illumination technology have developed, so has the frame grabber—now most common in a PCIe slot on the motherboard. Modern frame grabbers are capable of carrying interfaces such as LVDS, RS422, and Camera Link. Frame grabbers are also being developed to handle the newest of machine vision interfaces, CoaXPress.

The CoaXPress interface was recently adopted by the combined agencies of the Automates Imaging Association (AIA), European Machine Vision Association (EMVA), and the Japanese Industrial Imaging Association (JIIA), collectively known as G3. Merging the simplicity of coaxial cable with serial data technology, CoaXPress permits high-speed image data to be transferred over long distances in area-scan and linescan applications, even when captured by the largest, fastest, and most bandwidth-hungry of today’s CMOS sensors. This kind of application goes far beyond the capabilities of established interfaces.

CoaXPress details

CoaXPress (CXP) is a high-speed point-to-point serial communication standard for the transmission of video data, scalable over single or multiple coaxial cables. It has a high-speed downlink of up to 6.25Gb/S per cable for video, images, and data, plus a lower speed, 20Mb/S uplink for communications and control. Power is also available over the cable ("Power-over-Coax") and cable lengths of greater than 130 m may be achieved, much farther than twisted pair.

Industry analysts widely expect CoaXPress will be the fastest growing interface in machine vision over the next 3-4 years. This owes to a range of advantages including: low cost of standard 75 Ohm coaxial cables, ultrafast data transmission rates, and achievable longer distances. For even higher data rates, multiple CXP channels can be used. CoaXPress can be expanded to four ports, resulting in 25Gb/s of data throughput. Despite the long distances, CoaXPress permits trigger events to be sent from host to camera and vice versa with minimal latency and jitter.

Because it uses standard coaxial cable yet delivers impressive bandwidth, CoaXPress is drawing interest not only from the machine vision community but also from integrators in the medical, military, and security fields where legacy coaxial cable is often deployed. By “repurposing” already installed coaxial cables, CoaXPress eases the migration from analog to digital video.

To better appreciate these advantages let's look at an application example: license plate readers. In Europe, the standard license plate is large enough that it is easy to read, 18- to 20-in.-long plates, 4-in. tall, and large bold, unhindered fonts. The U.S. license plate is 12-in. x 6-in., and apart from up to seven alphanumeric characters, there is also a state name and sometimes an image on the plate. This leads to a lot of confusion at low resolutions, for example deciphering whether the plate of a car that drove through a toll booth without paying was ABC123 or A8CIZ3. The processing center would have to verify the car make and interaction with the registry, which in turn dramatically reduces efficiency. If the resolution and data delivery were sufficiently quick, it would be a simple read. However, while a higher resolution camera would offer the solution, an interface is needed to bring the data back to the processing center extremely quickly—a distance typically further than twisted pair cable can handle even with repeaters.

The CoaXPress interface will be of major benefit here. Several analog traffic cameras are on U.S. highways. This data is coming back at 11Mb/S over a coax cable from the camera to the computers. Consider the volume of data coming back at even one CXP link (650Mb/S). This would enable images of traffic on routes to be crystal clear and also allow for better information dissemination about traffic backlogs, accidents, or breakdowns. These images would be clear enough to be seen on a smartphone app. And because CXP offers Power-over-Coax, there would be no need for additional cabling work.

Additional CXP applications

CoaXPress will play a vital role in many aspects of machine vision in the coming years. As designers sit down with this new interface at their disposal, more ideas will be formed and CoaXPress will enable machine vision to perform more efficiently.

- Donal Waide is director of sales for BitFlow, Woburn, Mass. Edited by Mark T. Hoske, content manager CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske(at)cfemedia.com.http://%0Dwww.bitflow.com

www.bitflow.com

www.coaxpress.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.