Low maintenance 4-in-1 pH Probe

Yokogawa FU24 is a ‘four in one’ pH sensor designed to offer virtually maintenance-free operation and long sensor lifetime – especially in harsh applications involving severe temperature and pressure fluctuations.

Yokogawa

04/06/2012


YokogawaThe FU24 sensor incorporates a patented Yokogawa-designed bellows system which automatically compensates for the effect of pressure fluctuations. Such pressure variations can be highly detrimental to sensor operation, as they can initiate a pumping effect resulting from the expansion and shrinkage of the gel or liquid inside the sensor. The outcome is that the process liquid will start to ingress into the sensor and the reference voltage – and hence the pH measurement - will start to drift.

In the FU24 sensor, pressure fluctuations are automatically compensated by the built-in bellows up to 10 bar, making the sensor virtually insensitive to pressure variations. A positive overpressure maintained by the tension in the bellows generates a steady flow out of the sensor.

FU24 Features:

  • Low long-term cost of ownership
  • Low maintenance
  • Pressurized reference
  • High chemical resistance
  • Reduced cost to install system
  • 1 inch NPT connection
  • With adapter piece K1521JA compatible with existing F*20 assemblies
  • 4-in-1: pH, reference, temperature, liquid earth (ORP)
  • Reliability
  • High stability

For more information visit the Yokogawa website at www.yokogawa.com/us.

For more on industrial sensors, see: controleng.com/sensors



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.