Linear hall-effect magnetic position sensor IC

Honeywell SS39ET series has a low-cost, versatile SOT-23 subminiature surface mount package ideal for compact designs with tight space requirements.

Honeywell

03/13/2012


SS39ET subminiature Linear Hall Effect Sensor ICHoneywell is extending its Linear Hall-effect Sensor Integrated Circuits (IC) product line with the addition of the new SS39ET Series to its SS49E and SS59ET portfolio of low-cost Linear Hall-effect devices.

With the launch of the SS39ET Series, Honeywell’s Linear Hall-effect product family now consists of three package styles with different lead configurations:

  • SS39ET: subminiature SOT-23 surface mount package (tape and reel format)
  • SS49E: leaded flat TO-92 package (bulk packaging, 1000 units per bag), SS49E-T2 (straight leads), and SS49E-T3 (formed leads) on tape in ammopack (fan-fold) format
  • SS59ET: miniature SOT-89B surface-mount package (tape and reel format) 

“With the launch of the new SS39ET Series, customers can choose the package style and size to meet their application needs,” said Josh Edberg, senior global product marketing manager for Honeywell Sensing and Control. “Customers will appreciate the SS39ET Series’ SOT-23 subminiature footprint that takes up less space on the PC board, allowing more design flexibility and cost savings in their application.”
 
The SS39ET Series are designed to monitor magnetic fields from a permanent magnet or an electromagnet. All packages can be supplied on tape for automated, lower-cost assembly. These devices respond to both North and South poles, and can be powered with voltages as low as 2.7 V.
A wide temperature range of -40 C to 100 C [-40 F to 212 F] allows use in many environments, and the thermally balanced, integrated circuit provides stable operation over the full temperature range. Thin film resistors improve accuracy and provide a stable output. The energy-efficient, low current consumption of 6 mA at 5 V dc and the 2.7 V dc to 6.5 V dc supply voltage range allow circuit design flexibility.
 
Potential industrial applications for the SS39ET Series include:

  • Anti-tampering magnetic field sensing in smart remote utility meters
  • Basic current sensing for motor load monitoring, detection
  • Pump control in heavy-duty equipment and household appliances 
  • Simple linear or angular displacement sensing
  • Handlebar/throttle position sensing in e-bikes and scooters 
  • Current sensing in appliances 
  • Speed adjustment trigger in tools and appliances 
  • Magnetic code reading in safes, security, and building access control systems.

Potential medical applications for the SS39ET Series include:

  • Position sensing in infusion pumps

Learn more about Honeywell Sensing and Control 

http://sensing.honeywell.com/

Also see controleng.com/sensors. 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.