Isolated analog signal conditioner

The 8B43 analog signal conditioner by Dataforth includes 10 modules and has a special input circuit that provides protections against accidental connection of power-line voltages up to 240 V AC.

08/09/2012


The 8B43 analog signal conditioner by Dataforth includes 10 different modules and has a special input circuit that provides protections against accidental connection of power-line voltages up to 240VAC. Courtesy: DataforthDataforth's isolated analog signal conditioner, the 8B43, interfaces to dc linear voltage displacement transducers (LVDT) which operate on a 1 0V excitation voltage and up to 2 0mA of  excitation current.

The 8B43 family includes 10 different modules with input ranges from -1 V to +1 V through -5 V to +5 V. Each module isolates, filters, and amplifies a voltage input signal, then provides an analog voltage output.

Specific 8B43 DC LVDT applications have included measuring soil sample deformation under load to determine soil strength, controlling pill weight and thickness in making tablets from medicinal powder, continuously monitoring fluid levels as part of a leak detection system (using a hydraulic oil compatible module) and replacing limit switches to ensure higher resolution on bottle inspection machinery.

Signal filtering in the 8B43 is achieved with a 5-pole filter that is optimized for time and frequency response and provides 100 dB per decade of normal-mode rejection above 1 kHz. One pole of the filter is on the field side of the isolation barrier for anti-aliasing;  the other four are on the system side.

A special input circuit provides protection against accidental connection of power-line voltages up to 240 V ac, while clamp circuits on the I/O and power terminals protect against harmful transients. Isolation is provided by transformer coupling to suppress transmission of common mode spikes or surges. The module is powered from +5 V dc, ±5%.

Designed for installation in Class I, Division 2, hazardous locations, the 8B43 offers a high level of immunity to environmental noise.

Dataforth

www.dataforth.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.