Inspection System for Beer Keg Quality Assurance

Green Bay, Wis.-based Tosca Ltd. cleans and reconditions many different food-industry containers. Examples include: bulk cheese containers; bulk plastic bins, for pizza crust production and transportation; returnable plastic containers, for transporting produce and meat; and beer kegs. Several different brewers employ Tosca to repair and clean their kegs.

By David Thode and Josh Hemstreet

12/15/2005


Green Bay, Wis.-based Tosca Ltd. cleans and reconditions many different food-industry containers. Examples include: bulk cheese containers; bulk plastic bins, for pizza crust production and transportation; returnable plastic containers, for transporting produce and meat; and beer kegs.

Several different brewers employ Tosca to repair and clean their kegs. After repair of a beer kegs, valve inserts are placed back in the barrels and a retaining ring is positioned in the stem so the valve cannot pop out of the stem. Next, the keg is pressurized and checked for leaks prior to shipment.

Ifa retaining ring is not placed or properly seated, this could pose a quality issue for the customer. Tosca quality assurance personnel perform visual secondary inspections on 100% of their finished product to ensure that each barrel's retaining ring is properly inserted.

Curt Dhein, Tosca's Green Bay plant manager said, "This was very time-consuming, and we were sure there had to be a better way to ensure the retaining ring had been properly installed during our process. We had used vision systems in some of our other operations with good success, so we wondered if that technology would work in this application." Consequently, HiTech Control Systems Inc., also of Green Bay, was contracted to design a vision system to verify the presence of the retaining ring on kegs with slotted valves and notify the operator if a retaining ring is missing.

Seeing clearly

HiTech's system-integration approach encompassed:

  • Project characterization and management;

  • Vision design, programming, configuration;

  • Configuring inspection tools for:

  • Ring/no ring/partial ring,

  • Screw-in valve types;

  • Camera setup and lighting;

  • System startup, users' manuals and training;

  • Mounting equipment in panel;

  • Mounting a cloudy day illuminator in camera; and

  • Field service support;

There are two keg sizes and two valve-insert types—threaded and slotted—that go through inspection. Retaining rings are necessary in kegs using slotted valves, but are not used in kegs fitted with threaded valves. Keg color is either black or silver. "The highly reflective, stainless-steel keg-neck and valve posed a challenge for generating images," stated Josh Hemstreet, electrical engineer, HiTech.

The system must notify the operator if the retaining ring is not fully inserted. An exception is a second keg type that has a screw-in valve; it must be identified and automatically passed.

The retaining ring is properly placed at the first station. There the operator places a keg on the stem holder where a threaded valve is turned in and torqued to specification. A slotted valve is inserted and a retaining ring is placed on the plunger mechanism. After the operator pushes two buttons—one with each hand—the plunger is activated, pushing down on the valve. This allows the operator to insert the retaining ring between the valve and the end of the valve stem. Next, the operator presses the third button to retract the plunger mechanism.

The operator then moves the keg to the inspection station. Here the part is repeatedly positioned to within

Inspection

A continuous diffuse illuminator was selected to light the keg stem to avoid creation of image saturation areas. Inspection is initiated by a pushbutton. The keg remains at the inspection station until the vision equipment passes the keg.

If there is a threaded valve, or a slotted valve with a fully inserted retaining ring, a green light illuminates, and the keg is automatically moved to the pressurization station. If the retaining ring is not present, or partially inserted, a red light is activated, an audible alarm sounds, and the keg stays in the inspection station.

Vegetables too

Tosca also uses DVT vision systems for spinach crate inspection. DVT was used due to scalability and availability of no-cost programming-software and training. DVT programming software allows camera system connectivity from any company location via Ethernet link. HiTech is a certified systems integrator for DVT and Cognex vision systems.



Author Information

David Thode and Josh Hemstreet are operations manager and electrical engineer, respectively, with HiTech Control Systems Inc.




No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.