High-speed analog input card

Analog-to-digital converter offers four channels of 12-bit data acquisition.

08/10/2010


PCIe-1744, 4-channel, 12-bit, ultra-high speed analog data acquisition card with PCI express interfaceThe Industrial Automation Group of Advantech has introduced its PCIe-1744, a 4-channel, 12-bit, ultra-high speed analog data acquisition card with PCI express interface. Advantech says the new design is capable of handling analog-to-digital sampling simultaneously and independently on all four channels. The unit features multiple trigger modes and a 30 MHz sampling rate using independent A/D converters for each of the four analog input channels. Large sample buffers per channel help ensure all readings are securely captured.

PCIe, unlike previous PC expansion standards, is structured around point-to-point serial links, a pair of which (one in each direction) make up a lane, rather than a shared parallel bus. These lanes are routed by a hub on the main-board acting as a crossbar switch. The company says this dynamic point-to-point behavior allows more than one pair of devices to communicate with each other at the same time. In contrast, older PC interfaces had all devices permanently wired to the same bus, so only one device could send information at a time. This format also allows channel grouping, where multiple lanes are bonded to a single device pair in order to provide higher bandwidth.

Peter Welander, pwelander(at)cfemedia.com
Control Engineering

Visit the Control Engineering Information Control Channel.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.