High pressure inductive analog sensor

Balluff's analog sensor is rated up to 500 bar and is IP68 rated and is designed for application that involve control and service measurements of valves and position monitoring.

05/31/2012


Balluff's analog sensor is rated up to 500 bar and is IP68 rated and is designed for application that involve control and service measurements of valves and position monitoring. Courtesy: BalluffBalluff's high pressure inductive analog sensor is rated up to 500 bar. This high pressure sensor is ideal for valve control and hydraulic cylinder cushioning applications. Corrosion-resistant housing materials, high strength ceramic sensing faces and special sealing techniques allow service up to 500 bar or pressure.

Features include:

  • One design - two output models
  • Switching for final position detection
  • Analog for control of valves or immediate stop
  • Oil pressure up to 500 bar
  • IP68 in high quality
  • M12 stainless steel housing 0.5 to 2mm sensing range

The Balluff high pressure inductive analog sensors are designed for applications that involve the control and service measurements of valves, position monitoring in mobile hydraulic systems, parked positions of cranes, final position of installation supports, and control of agricultural technology.

Balluff Inc.

www.balluff.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me