SEARCH Archives
Loading
Sponsored by:

HANNOVER MESSE: Extended transport drive system

Beckhoff's XTS drive system combines rotary and linear systems for mechanical engineers.

04/26/2012


Hannover Messe 2012 logoThe XTS drive system (eXtended Transport System) from Beckhoff offers completely new freedom for mechanical engineering. XTS combines the previously separate advantages of two proven drive principles: Rotary and linear systems. The result is a new drive system that effectively turns the previous linear motor principle around. The motor is completely integrated together with power electronics and displacement measurement. One or more wireless movers can be controlled with high dynamics at up to 4 m/s on an almost arbitrary and flexible path. The XTS, with its compact design, revolutionises Drive Technology and makes completely new machine concepts possible.

XTS is an advanced mechatronic system containing all functions necessary for operation:

  • A modular, fully integrated linear motor with power electronics and displacement measurement in one device;
  • one or more wireless movers as the moving parts;
  • a mechanical guide rail;
  • an Industrial PC with TwinCAT control software

The desired geometries, lengths and radii are determined by the number and type of the components selected. Complex wiring and drag chains can be eliminated. In addition, the position measurement system is already integrated. The machine footprint is fully and efficiently utilised, since the outward and return path as well as the curves can be used for active material transport. In this way, not only is hardware saved, but so is expensive production space. Speeds of up to 4 m/s can be achieved with XTS while maintaining maximum positioning accuracy.

The new linear motor principle

Beckhoff's XTS drive system combines rotary and linear systems for mechanical engineers. Courtesy: BeckhoffThere are virtually no limits to the application possibilities of XTS: The movers can accelerate, brake, position and synchronise themselves. They can take up absolute positions and positions relative to each other; they can group themselves and accumulate; they can create clamping forces in motion, drive through curves and along straights, recover energy through regenerative braking and use both the return paths and the outward paths for transport purposes.

This new linear motor principle gives rise to completely new possibilities in Drive Technology:

  • Linear motor characteristics on an endless path;
  • any desired number of movers on a common path;
  • modular structure, simple adaptation to the application;
  • low spatial and power requirements;
  • simple implementation of demanding transport tasks;
  • low project engineering and assembly expenditure

Plug-and-play: The XTS system components

The XTS system is simple and modularly configurable: the motor modules form a complete unit with the movers and guide rails. They contain the electromagnetic coils and all other active functions necessary for the operation of the system. The only further requirements are a power supply and an EtherCAT connection. The motor modules contain no moving parts and are not subject to any wear.

The mover contains magnetic plates which, together with the coils in the motor modules, can generate propulsive forces. It absorbs the attractive forces of the magnets on both sides and compensates them as far as possible. This means that the rollers on the movers, which are equipped with a particularly low-wear plastic surface, can move at high speed in the guide rails. A mechanically robust encoder flag conveys the mover position to the motor module.

Flow of material in packaging and assembly technology

XTS can be used in an unlimited number of ways in the most diverse industries. The solution is predestined for high-speed material handling:

  • Push product, adapt product spacing, reduce or increase product speed;
  • clamp and move product;
  • transport and discharge product;
  • manipulate product: lift out, close, rotate, screw cap on.

An irregular product flow is isolated and transferred at a constant interval and constant speed to the next workstation. Products are picked up and transported from one workstation to the next. 

The distances in between are traversed at high speed if the path is free, or the products move in a travelling buffer to the destination. The products can be processed in parallel in groups at slow workstations. Fast stations only process one product at a time. The return path can always be actively used.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.