Fire alarm control panels

A new fire alarm control panel by Honeywell is designed to reduce installation/maintenance while increase its capabilities and life span.

06/08/2011


Fire-Lite Alarms by Honeywell has modernized two of its addressable fire alarm control panels with installer-requested features to reduce installation/maintenance time and enhance the systems' capabilities and life span. Version 3 of the MS-9200UDLS and MS-9050UD panels support more notification and ancillary devices while allowing for longer wire runs using most styles of wire. With fire alarm voice evacuation becoming more prevalent in the U.S. market, the number of speakers and strobes required has increased dramatically, creating a need for higher-capacity systems. On both panels, the addition of a second annunciator circuit, commonly used to tie in remote annunciators, printers, and more, allows for double the number of ancillary devices and double wire lengths that can be run in different directions using nearly any type of wire. A quick-remove chassis on both panels allows electronics to be removed from the backbox during the initial construction phase.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me