Fieldbus Foundation enhances physical layer specifications

Updates to H1 physical layer specifications promote better device installation and integration.

06/02/2011


The Fieldbus Foundation has announced enhancements to its open, non-proprietary Foundation fieldbus physical layer technology. The latest updates to the H1 (31.25 kbit/s) physical layer specifications will improve the robustness of fieldbus control systems by optimizing device interoperability and integration. End users will benefit from easier installation, faster commissioning and seamless startups.

Enhancements to the Foundation fieldbus specifications include:

  • Addition of a test procedure for isolated couplers to the existing Foundation fieldbus Coupler Test Specification. Registration of isolated couplers is now possible.
  • Improvements to the H1 Physical Layer Conformance Test Specification based on Action Requests received during the last few years. The most significant changes include the addition of a receive jitter test case and a device-coupler interoperability test.
  • Updates to the H1 Physical Layer Test Specification to remove obsolete profiles and align new references in the document with the current International Electrotechnical Commission (IEC) specifications. Coupler profiles were also added to the test specification.
  • Miscellaneous updates to the Foundation fieldbus Cable Specification.

Fieldbus Foundation Director-Fieldbus Products Stephen Mitschke commented, "The Fieldbus Foundation's rigorous interoperability test and registration procedures thoroughly examine all aspects of a fieldbus device. The latest enhancements to our physical layer specifications will strengthen this testing and provide end users with greater confidence that registered Foundation fieldbus devices can be employed in a tightly integrated, interoperable control system architecture."

Implementation of the new Foundation fieldbus H1 Physical Layer Test Specification Version 2.0 is not immediately required. However, fieldbus device developers are encouraged to start using the specification as soon as possible. The updated specification will become mandatory with the next major release of the Fieldbus Foundation's Interoperability Test Kit (ITK). Until then, developers can still provide proof of conformance to Version 1.5 of the specification when registering a device.

www.fieldbus.org

Fieldbus Foundation

See more industrial network news, products, and feature articles at www.controleng.com/networks.

Also www.controleng.com/wireless.

And the Fieldbus Facts Newsletter: http://www.controleng.com/index.php?id=3108.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.