Ethernet IO modules: Rugged, on-machine, high-speed, synchronized

Rockwell Automation EtherNet/IP-based on-machine distributed I/O has CIP Sync technology, an industry first, the company said. Allen-Bradley Slim ArmorBlock I/O modules have Sequence of Events (SOE) and Scheduled Output capability to improve response time and overall machine performance.

06/15/2012


Rockwell Automation EtherNet/IP-based on-machine distributed I/O has CIP Sync technology, an industry first, the company said. Allen-Bradley 1732E Slim ArmorBlock digital Scheduled Output module has Sequence of Events (SOE) and Scheduled Output capabilityRockwell Automation expanded its Allen Bradley ArmorBlock I/O line to help users deploy distributed I/O in high-speed applications. The new 1732E Slim ArmorBlock digital Scheduled Output module can schedule an output in 1 microsecond increments and trigger multiple outputs at high-speed intervals of 100 microseconds. This is useful in motion applications where higher resolution of outputs is required for more precise control and synchronization. By using CIP Sync distributed time synchronization, the new 1732E Slim ArmorBlock digital SOE input module can register any axis position within the system accurately with a single time-stamp input. It reduces wiring costs and installation time, compared with the conventional method.

“As synchronization is required to achieve precise coordination and control of high speed applications, the performance of the machine is often dependent on the controller’s scan time,” said Eddy Lek, distributed I/O product manager, Rockwell Automation. “Switching to a time-based I/O solution allows users to do predictive events and schedule outputs, which improves the coordinated response and overall manufacturing performance.”

The I/O offer a sealed housing rated for IP65/67/69K environments, which eliminates the need for a protective enclosure. Ideally suited for automotive, material handling and semiconductor applications, users can connect it directly to sensors and actuators using plug-and-play connectors, reducing wiring, labor costs and errors associated with long wiring runs.

The new 1732E Slim ArmorBlock I/O blocks include the 1732E-8CFGM8R, 1732E-IB8M8SOER and 1732E-OB8M8SR modules. Each ArmorBlock module is equipped with dual-port Ethernet for linear topology, as well as dual-port auxiliary power connectors for daisy chain of 24 V dc power.

http://ab.rockwellautomation.com/IO/On-Machine-Block-IO/1732-ArmorBlock-IO 

- Edited by Mark T. Hoske, content manager CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineermhoske@cfemedia.com.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me