Environmentally friendly cables

EcoCable and EcoFlex by Alpha Wire are nonhalogenic and meet RoHS and WEEE requirements. They are designed to be lighter and smaller than traditional PVC cable and can be used in extreme temperatures.

01/18/2013


EcoCable and EcoFlex by Alpha Wire are nonhalogenic and meet RoHS and WEEE requirements. They are designed to be lighter and smaller than traditional PVC cable and can be used in extreme temperatures. Courtesy: Alpha WireAlpha Wire's EcoCable and EcoFlex are designed to be up to 65% lighter and 47% smaller, with up to 91% lower outgassing than traditional PVC cable. The two control cables are nonhalogenic and contain no heavy metal pigments, allowing them to meet RoHS and Waste Electrical and Electronic Equipment (WEEE) requirements.

EcoCable offers space savings of up to 47% compared to traditional PVC control cable. For example, a 22 AWG PVC insulated cable has a diameter of 0.502 inches (12.75mm). The equivalent EcoCable has a diameter of 0.219 inches (5.56mm). Its counterpart EcoFlex offers space savings of up to 32% versus PVC and is rated for up to 1 million flex cycles. 

The initial EcoCable offering is a UL AWM 21510 and CSA Rated cable available in sizes ranging from 24 AWG (0.28 mm²) to 14 AWG (2.08 mm²) available in 100 ft and 1000 ft lengths. EcoCable is suitable for use in NFPA79 applications and is RoHS and REACH Compliant. Its temperature range of -50C to +105C exceeds that of standard PVC cable. 

EcoFlex is a UL AWM 21819 and CSA Rated flexible control cable available in sizes ranging from 28 AWG (0.09 mm²) to 10 AWG (5.32 mm²). It’s offered in 100ft and 1000ft lengths, with bulk available for larger quantities. With up to an 8x flexing bend radius and rated for up to 1 million flex cycles, EcoFlex is suitable for use in NFPA 79 applications and is RoHS and REACH Compliant. Its temperature range  is -40C to +105C static, and -5C to +105C while flexing.

Alpha Wire

www.alphawire.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.