EC: SureCross Q45 Wireless Photoelectric Sensor

Machine and Embedded Control - Discrete sensors: The Banner Engineering SureCross Q45 is the world's first completely self-contained wireless photoelectric sensor solution, designed to provide untethered communications for control and monitoring applications. This is a Control Engineering 2013 Engineers' Choice Award winner.

11/12/2012


The Banner Engineering SureCross Q45 is the world's first completely self-contained wireless photoelectric sensor solution, designed to provide untethered communications for control and monitoring applications. This is a Control Engineering 2013 Engineers' Choice finalist.The Banner Engineering SureCross Q45 is the world’s first completely self-contained wireless standard photoelectric sensor solution designed for control and monitoring applications. As an established leader in photoelectric sensors and wireless technology, Banner Engineering is the first and only company to develop a 100% self-contained wireless sensing solution with a proprietary, self-contained battery, radio and sensor all in one package. Featuring easy deployment and untethered communications, the SureCross Q45 provides the functionality, reliability, and determinism required for factory applications. 

The SureCross Q45 improves efficiency by monitoring and coordinating multiple machines and processes through its key performance features: - Proprietary power management delivers extended battery life up to five years on two replaceable AA Lithium batteries, depending on sensor and application - Long range communication of up to 3,000 ft/1 km line-of-sight minimum - Multiple I/O with support of a wireless network of up to 47 Q45 sensors per gateway - Deterministic PLC-level reliability - Built-in site survey capabilities - Robust, IP67/NEMA 6P protection against liquids and debris common to industrial environments.

With performance capabilities ranging from the detection of objects in simple presence/absence or alignment applications to call-for-parts and error-proofing in productivity solutions, the SureCross Q45 can accurately connect and solve applications that were difficult, costly or nearly impossible with conventional technologies. It is ideal for many applications, including cable replacement, moving applications, remote applications and productivity solutions. To meet diverse application requirements, models are available in Polarized Retroreflective, Convergent Visible, Remote Device Interface and Fiber Optic.

www.bannerengineering.com

www.bannerengineering.com/en-US/wireless/surecross_web_q45

Banner Engineering



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me