EC: NI CompactRIO

Machine and Embedded Control - PACs: National Instruments, NI CompactRIO. The new NI cRIO-9025 embedded real-time controller is a new addition to the NI CompactRIO platform that provides a more rugged -40 to 70 C deg extended temperature operating range along with a higher performance processor which makes it ideal for industrial and embedded engineers prototyping and deploying advanced monitoring and control systems. This is a Control Engineering 2011 Engineers' Choice (EC) Award winner.

11/01/2010


NI CompactRIO - The new NI cRIO-9025 embedded real-time controller is a new addition to the NI CompactRIO platform that provides a more rugged -40 to 70 C Â extended temperature operating range along with a higher performance processor which makes it ideal for industrial and embedded engineers prototyping and deploying advanced monitoring and control systems. This is a Control Engineering 2011 Engineers' Choice (EC) nominee.The new NI cRIO-9025 embedded real-time controller is part of the high-performance and reconfigurable NI CompactRIO advanced monitoring and control platform. The controller works with any of the existing CompactRIO reconfigurable chassis, which include field-programmable gate arrays (FPGAs) that are programmed using the NI LabVIEW 2010 graphical system design platform. Using LabVIEW and CompactRIO, engineers quickly can implement custom analog and digital control loops, along with high-speed signal processing algorithms to meet their advanced measurement and control application needs.

The NI cRIO-9025 features an industrial 800 MHz real-time Freescale processor running a VxWorks RTOS for deterministic, reliable real-time applications and contains 512 MB of DDR2 RAM and 4 GB of nonvolatile storage for data storage. The controller also provides dual Ethernet ports for network programming and communication, USB and RS232 ports for removable storage and connection to peripherals and dual power supply 9-35 V dc inputs. The cRIO-9025 controller is programmed with the LabVIEW Real-Time Module, which includes hundreds of built-in functions for signal processing, control, advanced mathematics, simplified interfacing to the reconfigurable FPGA and more. Additionally, LabVIEW provides the ability to take existing C code or text-based models and run them embedded on the NI cRIO-9025 real-time controller.

In addition to an extended operating temperature range, the new CompactRIO controller is available with conformal coating. This coating is a specially formulated thin film material applied directly to circuit boards within the cRIO-9025. It provides an impermeable seal to protect circuitry from humidity, moisture, mold, mildew, fungus, dust and corrosion caused by exposure to extreme environments. Application areas in which conformal coating can provide protection include marine, railway, automotive, factory monitoring, fuel cell testing and oil and gas refining.

www.ni.com

www.ni.com/compactrio

National Instruments

For more, see www.controleng.com/awards.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.