EC: Belden DataTuff 600V Cat 5e AWM-rated Cable

Network Integration - wire, cable, cordsets, connectors - Belden. Belden DataTuff 600V Cat 5e AWM-rated Cable - Unlike traditional Ethernet cables, Belden's 600V Cat 5e AWM-rated Cables are able to be used reliably in particularly tough EMI environments, i.e., motor control centers and switch gear applications. This is a Control Engineering 2011 Engineers' Choice (EC) Award winner.

11/01/2010


Belden DataTuff 600V Cat 5e AWM-rated CableWith the advance of Ethernet technology now reaching motor control centers (MCCs) and switch gear, the Ethernet cabling component must be especially reliable and robust.  In MCCs, drives could produce enough EMI to interfere with many traditional Ethernet cables.  Moreover, the need to monitor and control these devices may demand that the cable enter the MCC.  As a result, an Ethernet cable with excellent noise immunity and the ability to run on or near listed devices is needed.

Belden's DataTuff Industrial Ethernet Cat 5e 600V Cables provide assured performance and reliability in highly concentrated EMI environments, such as those in listed MCC and switch gear applications.  The AWM rating allows the cables to be used on or within a listed cabinet or machine, as well as in more traditional industrial Ethernet applications.

The DataTuff 4-pair shielded cables offer exceptionally rugged construction to provide superior performance, reliability and noise immunity. They feature an overall shielded design with 24 AWG Bonded-Pair solid bare copper conductors, polyolefin insulation, a 24 AWG stranded tinned copper drain wire, and an industrial-grade oil- and sunlight-resistant PVC jacket. One cable style (Part No. 7958A) has an overall Beldfoil shield to meet the EMI requirements of most plant environments, this cable is MSHA approved.  The other style (Part No. 7957A) has an overall Beldfoil shield + 70% tinned copper braid, making it suitable for use in more extreme EMI environments.  Both cables are Ethernet/IP compliant.      Belden's patented Bonded-Pair construction contributes to the cabling's electrical stability and performance.  In Bonded-Pair cables, the conductor insulations of each of the cable pairs are affixed to each other along their longitudinal axes to maintain conductor concentricity and ensure that no performance-robbing gaps between conductors can occur, before, during and after installation. Belden calls this unique capability Installable Performance.

www.belden.com

Belden

For more, see www.controleng.com/awards.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me