Drives optimize energy efficiency, reduce control room, panel space, cooling costs
Up to 68% smaller than previous generation drives, compact D-frame drives from Danfoss VLT Drives are optimized to deliver highly reliable performance in the 125 – 450 HP range while exhausting 90% of the drive-generated heat outside the enclosure via the backchannel.
Source: Danfoss VLT Drives
Danfoss D-Frame VLT Drives are available in a power range from 125-450 hp (90-315 kW) and up to 68% smaller than previous generation D-Frame drives, new D-Frame drives require significantly less panel or wall space than previous models which were already among the smallest in their class. This reduces installation costs and increases installation flexibility. These drives also leverage back channel cooling to remove 90% of the heat generated by the drive, reducing both up front and ongoing costs and making them an ideal panel building solution.
“With ever-increasing demands for improved efficiency and reliability in drive technology, OEMs, panel builders and end users are looking for new technologies that can save energy, reduce costs and help simplify operations in a solution that will provide trouble-free operation for years,” said Greg Reichelt, Product Manager High Power Drives, North America. “The new D-Frame VLT drives deliver on each count. Not only are these drives among the smallest in their class, they also include an array of efficiency and safety enhancing options as standard features, enabling customers and end users to reduce both initial and ongoing operating costs.”
The new drives are available with IP20, IP21 (NEMA 1) or IP 54 (NEMA 12) enclosure protection ratings. For robust protection they also come standard with conformal coated printed circuit boards, which together with the optional heat sink access panel, help to extend drive lifetime and reliability. The new units can be factory-fitted with optional semiconductor fuses to further reduce installation costs. Additional factory-fitted basic input options, such as mains disconnect, contactor and circuit breaker, eliminate the need to install these basic options externally.
New D-Frame drives also use Danfoss’ unique and innovative back-channel cooling concept to keep electronics safely within optimal operation temperatures. The big advantage of back-channel cooling is that system installation and operating costs can be dramatically reduced.
“Using a ducted back-channel, air is allowed to pass over the unit’s heat sink with minimal air passing through the electronics area. This way 90% of the heat generated by the drive is exhausted directly outside of the enclosure, improving reliability and prolonging the lifetime of the unit. An IP54 (NEMA 12) seal between the back- channel cooling duct and the electronics area of the VLT drive helps to significantly reduce temperature rise and contamination of the electronic components,” explained Reichelt.
Danfoss provides energy-efficient solutions that help save energy and meet the challenge of climate change. Key competencies are cooling of food, air conditioning, control of electrical motors and heating in buildings – as well as solutions for renewable energy such as solar power. Danfoss also comprises Sauer-Danfoss that is among the world’s leading manufacturers of mobile hydraulics. The 77 year company employs 26,000 employees globally and has 140 sales companies globally.
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.