Data logging, com port troubleshooting software updated

Windmill Software’s newest version of the ComDebug data logging and com port troubleshooting software allows users to quickly identify and correct communication errors.

09/30/2011


Windmill Software has announced a new version of the ComDebug data logging and com port troubleshooting software. The new version works with Windmill 7 64-bit, as well as Microsoft Windows, lets users enter and display data in hexadecimal code, ASCII code, or binary format, and logs data from serial instruments such as PIC Microcontrollers, RFID readers, PLCs, and data loggers.

ComDebug from Windmill Software is a data logging and com port troubleshooting software. Courtesy: Windmill Software

The software collects data from devices connected to the PC's com port over RS232, RS422, RS485, and Modbus. A terminal emulator lets users troubleshoot serial port connections. When monitoring com port communications, users can reportedly see all bytes sent and received, including non-printing characters like carriage returns.

With ComDebug users can quickly identify and correct communication errors, according to Windmill Software. The software can send and receive unsigned integers, single bits, floating points, 16-bit 2s complement integers, and other types of data. It can control the state of the PC's serial port output lines - setting them high or low - and show users the state of the port input lines.

Windmill Software

www.windmill.co.uk

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me