Configurable digital input and output module

The Wago IP67 Speedway 767 is designed to run in direct input, direct output and mixed digital IO modules.

11/16/2011


The IP67 Speedway 767 by WAGO is designed to run in direct input, direct output and mixed DIO modules. Courtesy: WAGO CorporationTwo eight-channel, configurable Digital Input/Output (DIO) Modules have joined Wago Corporation's IP67 Speedway 767 I/O-System. Configurable channel-by-channel, the 767-5801 & 767-5802 modules (24 V dc, 0.5 A) run in direct input (DI), direct output (DO) or mixed DIO modes. This versatility, and a segment-leading -25 C to +60 C operating temperature range, enables users to methodically tailor Speedway to meet application requirements.

767-5801 (8xM8 connectors) and 767-5802 (4xM12 connectors) record binary signals from sensors, proximity switches and controls actuators, such as, dc contactors or indicators. Capable of channel and module diagnostics, the 8DIO Modules provide parameterization of filter, inversion, substitute value strategy, manual mode and online simulation. Additionally, the modules can be configured with two 1 kHz counters with event, gateway time or pulse duration modes. They can also directly switch module outputs based on counter status.

Speedway 767 takes controls out of the cabinet and directly to applications via rugged, machine-mountable controllers and modules. It accommodates up to 64 I/O modules/station, 8 channels/module, 512 channels/station and 50 m between digital, analog or specialty modules. M8/M12 molded cables handle all power and signal transmission. The system is programmable via CoDeSys 3.0 and configurable via FDT/DTM technology. Supported protocols include: EtherNet/IP, Modbus/TCP, ProfiNet, Profibus, DeviceNet, and CANopen.

www.wago.us 

Wago Corporation

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me