Clemson students modify machine to make airport runway safer
Seven Clemson University students modified a mobile drill press to retrofit a section of runway at Greenville Downtown Airport in South Carolina that halts overrun aircraft.
Clemson researchers redesigned and modified a mobile drill press to retrofit a section of a runway that halts overrun aircraft, ultimately minimizing aircraft damage and passenger injury.
The process of retrofitting the end of a runway at Greenville Downtown Airport required more than 80,000 holes to be drilled in the concrete. Pace Pavement Technologies Inc. recognized that manually drilling the holes was not an option and there needed to be a more efficient and accurate way to drill.
“We visited several machine shops and pneumatic suppliers and received minimal assistance in the design and build of a mobile drill press,” said Carl Pace, president of Pace Pavement Technologies Inc. “Clemson University stepped up to the challenge and enjoyed taking on this project.”
Seven Clemson University student researchers and their faculty adviser met with representatives from Pace Pavement Technologies Inc. to discuss the design problems and challenges related to their mobile drill press.
“We needed to reduce the weight of the machine by half so as to not cause any damage to the pavement underneath,” Pace said.
The students began by redesigning the undercarriage and modifying the wheels to evenly spread the weight of the machine and reduce ground pressure.
“Clemson University student researchers truly went above and beyond their call of duty by not only reducing the ground pressure of the mobile drill press, but also improving the machine's overall performance and maneuverability,” said Gregory Mocko, an assistant professor in Clemson’s mechanical engineering department.
The students improved the overall performance of the machine by altering the plumbing, developing a gauge to adjust each drill simultaneously and adding a device that allows the operator to better control drill depth. They also published an operations and parts manual.
“I was overjoyed to have young minds really focused on this project,” said Pace. “They gave this project the attention that it deserved and I truly hope we have the opportunity to work with Clemson again.”
Mechanical engineering researchers Gregory Mocko, Mark Connelly, Curtis Duckett, Brock Fitschen, Shane Reid, Samuel Smith III, Chris West and Austin Wise completed the mobile drill press project.
Clemson University
Pace Pavement Technologies, Inc.
- Edited by Chris Vavra, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.
Click here to visit the Case Study Database and upload your case study.