Choose the right industrial connector

Evaluate application and environment to determine the best connector to incorporate into an industrial design or upgrade.

Lynne Keener

06/07/2012


Mencom Corp. offers industrial Ethernet connectors. Courtesy: MencomDetermining the connector to incorporate into an industrial design or upgrade is simply a matter of evaluating the application needs and environment. Start by asking yourself, “What type of transmission do I need?” and “What are my environmental conditions?”

Are your connection points needed for power, communication, signaling, or a combination? This is your first variable. What is your transmission requirement? Then determine the number of contact points needed, the current (amperage) requirements of the application, and the space constraints, if any. And, if using a heavy-duty rectangular connector, determine the wire termination method for the contact pins (spring, clamp, or screw). For many power (under 15 amps), signaling, and communication applications requiring fewer than 20 contact points, an overmolded circular connector offers a durable, economical, and reliable solution. Connector solutions requiring higher current carrying capacity or a greater pin count can often be found with a heavy-duty rectangular connector.

When the application calls for communication via an industrial protocol, specific network cordsets can be used. Whether using DeviceNet, Profibus, industrial Ethernet, Foundation Fieldbus, or one of many other protocols, each has its own connector design and often a specialized wiring code.

The application environment is also very important in determining what connector to choose. This factor will dictate what cable jacket should be used when considering a molded cordset. If the application is such that the cable needs to be protected from weld slag, TPE might be the best choice. If lubricants and coolants are prevalent, PUR would work. An application with continuous movement may require a cable with a high flex rating. Most standard applications can be addressed with a simple PVC jacketed cable. Selecting the correct cordset for the environment in the beginning can save money and time in the long run, by avoiding unneeded downtime, troubleshooting, and premature replacements.

Mencom Corp. offers cordsets for specific industrial protocols, such as DeviceNet, Profibus, industrial Ethernet, Foundation Fieldbus, and others. Courtesy: MencomUsing high-quality overmolded cordsets, and the proper mating receptacles, an IP67 rating can be achieved to accommodate various industrial environments. IP67 indicates that a connector is protected from dust and will withstand being immersed in water for a limited amount of time. This rating is sufficient for most industrial applications.

For wiring machines and system controls, legacy standards such as the MIN family of circular connectors still prevail as do the hard-to-match rectangular connectors. After evaluating power needs and environment, your choices are usually clear. When we include network configurations, the options expand to include bus networks and Ethernet. Micro-connectors for each of these formats are easy to find. Keep in mind that all connectors are not equal. Quality of components leads to reliability. At the end of the day, systems are only well connected when they’re running.

- Lynne Keener is marketing coordinator for Mencom Corp. Edited by Mark T. Hoske, content manager CFE Media, Control Engineering, Plant Engineering, and Consulting-Specifying Engineer, mhoske(at)cfemedia.com.

www.mencom.com 

ONLINE extra -  Founded in 1987, Mencom Corp., located in Oakwood, Ga., provides industrial electrical connectors. Mencom is among the last remaining manufacturers of U.S.-made electrical cordsets, Keener said. 



Anonymous , 02/25/13 10:46 PM:

Determining the connector to incorporate into an industrial design or upgrade is simply a matter of evaluating the application needs and environment. You have to make clear the problem.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.