BAS motor controls with auto run, predictive calibration

The BAS motor controls from Cerus Industrial accept dry voltage inputs and include other options like auto run and predictive calibration. One model accepts up to 600 V AC and motor loads up to 40 A.

11/27/2012


The BAS motor controls from Cerus Industrial accept dry voltage inputs and include other options like auto run and predictive calibration. A single model accepts up to 600VAC and motor loads up to 40A. Courtesy: Cerus IndustrialThe BAS motor controls from Cerus Industrial incorporate the company’s Smartstart Control Module for seamless integration with digital controls. The starters accept dry voltage inputs (wide range 12 V ac-250 V ac) for activation by control systems without interposing relays. Other control options include auto run, fireman’s override, fault, proof of flow (detects loss of load), and SmartStart predictive calibration (fault alarm). Integrated LED pilot lights and Hand/Off/Auto keypad are standard, simplifying unit setup and verification.

A single model accepts 208-600 V ac and motor loads up to 40 A, eliminating discrete thermal overloads and numerous contactor coil voltages typically required with other motor starters. The broad operating ranges enable distributors to eliminate thousands of dollars on unnecessary stock and mis-sizing issues. 

Upon motor start-up, the electronic Smartstart overload allows the starter to look for a safe operating range based on motor starting current. If the starter isn’t calibrated within that range, an alarm is activated and the starter contactor is opened. This feature is meant to protect against operators increasing the overload to overcome motor jams or other impedances and to provide base line protection should the starter not be calibrated. The BAS with Smartstart also protects against locked rotor, stall, and other undesirable starting conditions.

Cerus Industrial

www.cerusind.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.