Better mix: raise high the outdoor air inlet

Editor's note: "The Right Mix" (Oct. 2001, p. 69) author Gene DeJoannis, P.E., supplies an addendum to his story.

In a recent article in CSE, I wrote about the difficulty of insuring good mixing in large factory packaged air-handling units (AHUs), and proposed a compact mixing device to physically "tunnel" cold air into the warm return-air stream—the "Injecti-mixer." Although small air handlers permit outdoor air to be connected to the return duct before the AHU—thereby achieving good mixing—I commented that this is not practical for large AHUs because the ducts are so large they do not permit enough room. But there is a way: In cases where the AHU is backed up against an outdoor-air plenum, with the return or exhaust fan suspended in-line in an overhead return duct, the outdoor air plenum can be moved from the floor to ceiling of the mechanical room. This way, the return-air damper is installed in the room side of the outdoor-air plenum and the return duct connected to it. Note that the outdoor- and return-air streams enter nearly opposite each other and both must turn 90° downward and then 90° horizontally to enter the AHU. Although it is risky to predict air-mixing behavior, it seems reasonable that this arrangement will mix air better than traditional practices. Additionally, this reduces the likelihood of pulling in dirt as the inlet is elevated above the outside roof or surface.

GENE DeJOANNIS, P.E., van Zelm Heywood & Shadford

Integrity of fire cabling questioned

Mineral insulated (MI) cable manufacturer, Pyrotenax, has a videotape demonstrating a danger of circuit-integrity cable. When the insulation "ceramifies," it creates a flammable smoke which can spread fire through conduit wired with the U.L. 2126-approved cable. "Circuit Security," (Oct. 2001, p. 55) is silent on this aspect.

HERBERT ARGINTAR, P.E., NSPE

Author Dean Wilson's response: I am not familiar with the video and feel that it would be inappropriate for me to comment on these allegations until I view it myself. With regard to the general topic of smoke migration through conduit: This subject has been discussed in various forums over the years, and I am not aware of any notable fire occurring where propagation of smoke through the conduit played a significant ro le in physical damage or the threat to life.

Editor's note: Pyrotenax, Trenton, Ontario, unveiled the above-mentioned video at this year's NFPA conference. Those interested in the test can learn more at the company's web site at www.pyrotenax.com

Email
Print
Reprint
Learn RSS

Talkback

We would love your feedback!

Post a comment

» VIEW ALL TALKBACK THREADS

Related Content

Related Content

 

By This Author



SPONSORED LINKS

 
Advertisement
Sponsored Links

More Content

  • Blogs

Blogs


Sorry, no blogs are active for this topic.

» VIEW ALL BLOGS RSS

Advertisements





NEWSLETTERS
Plug in and get the latest CSE news, trends and industry updates delivered directly to your inbox!

Green Scene
CSE Codes & Standards
CSE NewsWatch
CSE Fire and Life Safety Solutions
CSE Business of Engineering Management Report
CSE Electrical Solutions
CSE HVAC Solutions
Pure Power
CSE Product Showcase
©2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites