ASHRAE Publishes New Standard 62.1

By Consulting Specifying Engineer Staff -- Consulting-Specifying Engineer, 5/24/2007 6:18:00 AM

ASHRAE has published the latest version of ANSI/ASHRAE Standard 62.1-2007, Ventilation for Acceptable Indoor Air Quality, which sets minimum ventilation rates and other requirements for commercial and institutional buildings. The new 2007 ventilation standard contains key changes impacting ventilation system designers and their designs.

"Standard 62.1 has served the building industry and the public as the most prominent standard on ventilation for indoor air quality," Dennis Stanke, committee chair, said. "Changes in the 2007 standard build on the improvements published in the 2004 version, providing additional guidance for designers of building ventilation systems." The new standard includes requirements for the separation of areas with environmental tobacco smoke (ETS) from areas without ETS in the same building. Although some local building and health codes prohibit smoking indoors in many buildings and locations, other codes allow smoking in designated areas. In buildings that allow smoking in designated areas, effective separation of ETS areas ensures "ETS-free" areas contain little or no ETS-related contaminants. The new separation requirements help designers ensure effective separation, according to Stanke. Another change clarifies of how designers must analyze mechanical cooling systems to help limit space relative humidity. Many buildings suffer from air quality problems related to dampness, including mold and other microbial growth. In the past, the standard required a design analysis at specified load conditions, in an effort to demonstrate that a given design approach in a given climate could successfully limit space RH to 65 percent or less. "Those load conditions could be confusing and difficult to establish," Stanke said. "The new requirements include a specific easy-to-establish load condition. Each system must be analyzed to check its dehumidification performance at this challenging condition to help designers make system configuration and control choices that reduce the likelihood of high-humidity problems in buildings."

Other changes include:

• Additions to Table 6-1 of minimum outdoor air requirements for dwelling units in high-rise residential buildings. These requirements apply to residences in buildings over three stories. Low-rise residential buildings are covered by ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.

• New or previously overlooked occupancy categories. In response to proposed changes from users of the standard, ASHRAE added several occupancy categories to Table 6-1 with associated minimum outdoor air rates. These include, for example, daycare sickrooms, university/college laboratories, break rooms and coffee stations, and laundry rooms.

ASHRAE Standard 62.1-2007 is available at www.ashrae.org.

Email
Print
Reprints/License
RSS
Talkback
Related Content

No related content found.

Also by CSE Staff

Reed Business Information Resource Center

Featured Company


Most Recent Resources

Advertisement
Sponsored Links
More Content
  • Blogs

Michael Ivanovich

Give and Take

Michael Ivanovich, Chief Editor, Consulting-Specifying Engineer


November 06, 2009
Responding to Ft. Hood: Bibliography of Mass Notification System Articles
As I watched the television news stories covering the Ft. Hood massacre, I was...
More

David Sellers

A Field Guide for Engineers

David Sellers, Senior Engineer, Facility Dynamics Engineering
November 03, 2009
Of Mice and Energy Conservation
Michael Ivanovich’s recent blog post about the mouse in his house reminded...
More

VIEW ALL BLOGS RSS

Advertisement
EGSA Web Banner_10
NEWSLETTERS
NewsWatch
Business of Engineering Management Report
Fire, Security, Life-Safety Newsletter
Electrical Newsletter
HVAC Newsletter
Pure Power Newsletter
Product Showcase Newsletter
Greenscene
CSE Codes & Standards



Please read our Privacy Policy

About Us   |   Advertising Info   |   Site Map   |   Contact Us   |   Free Subscription   |   Affiliate Links   |   RSS
© 2010 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites