Life safety systems at The Palmer House

The Palmer House has enhanced life safety systems to improve public safety in a grand Chicago hotel.

By Ralph E. Transue, PE, The RJA Group Inc., Chicago -- Consulting-Specifying Engineer, 1/1/2009 1:00:00 AM

View the full story, including all images and figures, in our monthly digital edition

After losing the original Palmer House Hotel to the Great Chicago Fire only 13 days after the hotel opened, Potter Palmer replaced it with an elegant new Palmer House, which opened in 1873. The seven-story hotel featured noncombustible construction, elevators, electric lights, and telephones in guest rooms. Commercial growth in Chicago supported construction of a new 25-story noncombustible hotel building adjacent to the existing hotel in 1927. That addition provided a new main entrance and grand lobby with ceiling murals of Greek mythology and ornate plaster work, an attraction even today.

Hilton Hotels Corp. bought the property in 1945, and it has been operated as one of Hilton’s premier properties since then. In 2005, Thor Equities acquired the property with a commitment to restore its grandeur and revive its mercantile face on Chicago’s State Street.

The Palmer House is the longest continuously operating hotel in the United States. Each owner has added life safety features to the property as the hotel has continued to maintain its reputation for quality as a world-class hotel.

Improving egress

Thor’s recent renovation project increased the property’s retail space from 50,000 to 150,000 sq ft and provided interior space to add three new interior protected exit stairs to improve egress capacity. The new stairs discharge directly to the outside, which permitted the removal of unsightly fire escapes from the State Street façade.

When the original buildings were completed in 1873 and 1927, the egress stairs discharged into the street-level arcade or other levels higher in the building. This was a common design practice for major hotels at the time. Although the building included many stairways, only one was continuous from the roof to the basement levels. The recent renovation project has improved the egress system by adding the three interior protected exits, which:

  • Connect the previously existing stairs serving guest room levels to exits that discharge directly to the outside at grade level

  • Increase exit capacity from the meeting room and ballroom levels.

Another improvement in the renovation project is the addition of fire-rated separations on guest room and meeting room floors to provide horizontal exits. This enhances public safety for both able-bodied and disabled occupants by providing separation and areas of refuge.

Entrance/exit doors, canopies, and corridors on the street level were improved to enhance the exterior appeal and permit expansion of the spaces dedicated to retail use. 

See Jeffrey Tubbs' article from the September issue of CSE to read more about egress design strategies.

Automatic sprinklers

In 1987, Hilton added automatic fire sprinkler systems in a major retrofit project covering all guest room and back-of-house floors. Quick-response sprinklers were selected for guest rooms to maximize response for life safety. The installation did not cover the ornate main lobby and the Empire Room in deference to the desire to protect the unique construction and décor of those well-known spaces. The lobby was covered by a projected-beam-type smoke detector until it was later covered by automatic sprinklers.

Hilton responded to the challenge of automatic sprinkler coverage in the ornate main lobby and the Empire Room in a subsquent project. The design and installation of the system was controlled carefully to conceal the piping and place the sprinklers in locations that harmonize with the unique décor, while conforming to coverage ratings. Placing the sprinklers in unobtrusive locations meeting applicable installation standards was a challenge met by attention to detail. The sprinkler locations were selected to fit unobtrusively into the pattern of plaster décor and coloring where sprinklers were to be visible. Other sprinklers were installed in previously existing openings in the plaster work. The result is that to the casual observer the sprinklers are not noticeable. It takes a trained eye to see them.

Fire alarm and smoke detection

The fire alarm and automatic fire detection systems have been installed and upgraded in several iterations. The most recent project was completed at the end of 2008; workers installed a high-rise fire alarm system in full compliance with the Chicago Building Code. The fire alarm replacement project proceeded in parallel with Thor’s renovation project and covers all of the hotel and retail areas. The system it replaced originally had been designed and installed by Hilton as a voluntary life safety system in accordance with national standards because the City of Chicago had no retroactive code requirement for such a system at that time. The first phase of the system was completed in 1985, including automatic fire detection in corridors and common spaces, voice and tone notification through speakers in corridors and common areas, and a firefighter two-way telephone communication system in major stairways. That system was extended to monitor the automatic sprinkler systems that were completed in 1987.

In time, Chicago enacted an ordinance that required fire detection and alarm systems in existing high-rise hotels. Hilton applied for and obtained the city’s approval of the existing system—with certain changes to more closely conform to Chicago practice—in 1997.

Single-station smoke alarms had been installed in guest rooms in 1982 and remain the method used for early warning to guests of the presence of a fire in the individual guest rooms and suites.

By 2003, the fire alarm system control equipment was becoming difficult to maintain due to decreasing availability of parts and electronic subassemblies. The decision to replace the alarm system was made in 2004 and included a major life safety improvement—the addition of notification speakers in every guest room. Hilton awarded the contract in 2005 and coordinated it to coincide with Thor’s renovation project.

The timing of contract awards presented a challenge to the fire alarm system designers and contractors. The fire alarm replacement project had been planned and bid based on the property configuration before the Thor acquisition. The system design and installation had to be revised to respond to the new configuration of the Thor renovation project, yet the renovation design and installation commenced after the fire alarm system replacement was already in progress. The challenge was met by close coordination among the designers and contractors who were not connected by contract, but who responded as a team to the interests of Hilton and Thor.

In addition to the improved guest room emergency voice notification system, the new system provides many more rooms for hearing-impaired guests equipped with strobe light notification appliances. In response to the Illinois Accessibility Code, Thor’s renovation project included a major increase in the number of guest rooms equipped for disabled guests, which also include special alarm system features. Disabled guests receive an audible and visible alarm notification signal if a fire is detected in their guest room or if the notification appliances are activated on their floor.

A grand hotel

A great deal of Palmer House business is tied to Chicago’s success as a convention city. The hotel itself provides assembly and exhibition facilities for large and small groups. A recent renovation of the exhibition space included installation of smoke detection and smoke removal systems as required by the Chicago Building Code for new construction of exhibition spaces exceeding 10,000 sq ft.

The Grand Ballroom, Red Lacquer Room, other assembly spaces, and the many smaller meeting rooms have been equipped with code-conforming audible and visible emergency notification speakers and strobe lights.

Since Hilton acquired the property in 1945 and as Thor has committed the resources to improve the property’s retail and hospitality presence, both owners have enhanced life safety systems to improve public safety in a grand Chicago venue.

These actions enable The Palmer House to remain a premier destination hotel for many years to come and enhance the rebirth of State Street as a commercial and mercantile hub of the city.

Author Information
Transue is a senior consultant for The RJA Group Inc. He is a principal member and former chairperson of the NFPA Technical Committee on Telecommunications, a principal member of the NFPA Technical Committee on Protected Premises Fire Alarm Systems, and a member of the Society of Fire Protection Engineers’ Engineering Education Committee.
Email
Print
Reprints/License
RSS
Talkback
Related Content
Reed Business Information Resource Center

Featured Company


Most Recent Resources

Advertisement
Sponsored Links
More Content
  • Blogs

Sorry, no blogs are active for this topic.

VIEW ALL BLOGS RSS

Advertisement
NFPA 2010
NEWSLETTERS
NewsWatch
Business of Engineering Management Report
Fire, Security, Life-Safety Newsletter
Electrical Newsletter
HVAC Newsletter
Pure Power Newsletter
Product Showcase Newsletter
Greenscene
CSE Codes & Standards



Please read our Privacy Policy

About Us   |   Advertising Info   |   Site Map   |   Contact Us   |   Free Subscription   |   Affiliate Links   |   RSS
© 2010 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy