New Products for HVAC and Refrigeration

Refrigerant retrofit bulletin, energy management guidelines, glycol unit coolers and wireless gas detection.

08/06/2007


Refrigerant bulletin provides guidelines for refrigerant changeover from HCFC R-22 to HFC R-422A and HFC R-422D. The bulletin, "Refrigerant Changeover Guidelines %%MDASSML%% HCFC R-22 to HFC R-422A/D," is for Copeland Discus compressors and is part of the manufacturer's ongoing stewardship campaign to promote environmentally responsible refrigerant solutions. To downloading the application engineering bulletin from Emerson Climate Technologies, click here .

Energy management guidelines detail the cost impact of wasted energy in industrial buildings and processes, and explains the solution steps to reduce the energy component of manufacturing costs. The presentation shows how when energy costs are treated as a component of cost-of-goods-sold, it becomes easier to understand the importance of managing the cost, much like labor or raw materials. To download the guidelines from CECO Environmental, click here .

Glycol unit cooler product lines support a growing demand for secondary loop refrigeration systems in supermarkets. A supermarket may contain up to 5,000 lbs. of refrigerant circulating through walk-in coolers and display cases, and experience leak rates of up to 30%. In addition to harming the environment, these leaks negatively impact the profitability of supermarkets, as it is costly to clean up and replace lost refrigerant. A secondary loop refrigeration system uses glycol as a secondary fluid to cool the supermarket refrigerated spaces that may come in contact with food. Glycol is non-toxic, non-flammable and does not contribute to global warming. For more information about systems from Heatcraft Refrigeration, click here .

Wireless gas detector is designed to monitor carbon monoxide and nitrogen dioxide in parking structures. In contrast to traditional hardwired gas detectors, the device is said to offer significant installation, maintenance and energy savings, plus greater operational flexibility and reliability. Advantages include no wires, conduit or extra materials; automatic configuration upon activation; and hot-swappable, plug-in cartridge. For more about the 301W detector from Honeywell, click here .





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me