Wireless corrosion and sand monitoring system
Emerson Process Management's Roxar CorrLog + Sandlog wireless transmitters are designed to integrate downstream and upstream assets.
Emerson Process Management's Roxar CorrLog + SandLog Wireless transmitters combine Emerson’s Smart Wireless technology with Roxar corrosion and sand monitoring instrumentation to provide a wireless integrity management solution for protecting operators’ downstream and upstream assets.
At a time when operators are facing continued production challenges from sand and corrosion and all too often a lack of integration across their asset integrity management systems, the new transmitters are designed to provide accurate online monitoring of sand and corrosion, extending equipment life and increasing production from reservoirs.
“We all know how important it is for operators to protect the integrity and extend the life of their downstream and upstream assets, and we also know that the age-old threats of sand and corrosion remain significant obstacles to the successful flow of hydrocarbons from refinery to reservoir,” said Kjell Wold of Emerson Process Management.
Key benefits of the Roxar CorrLog + SandLog Wireless transmitters include:
- Flexible and cost effective. The wireless transmitters will result in a significant reduction in installation costs compared to wired online systems and will also allow for monitoring in previously inaccessible areas. Furthermore, a 20 meter probe cable between probes and transmitters ensures increased flexibility, optimum positioning and easy maintenance.
- Increased accuracy and reliability with a low risk of signal loss in high risk applications, better data and trending, and highly sensitive sensors generating improved information for asset integrity protection. All probe functions (Electrical Resistance (ER), Linear Polarization Resistance (LPR) and Galvanic) are integrated within the transmitter and multi-element sand/erosion probes are incorporated within the Roxar SandLog transmitter to provide increased accuracy.
- Seamless integration. The Roxar CorrLog + SandLog Wireless transmitters are one element of a complete asset integrity system with direct integration through the Smart Wireless Gateway and access to Roxar Fieldwatch, Emerson’s windows-based field monitoring system for advanced data analysis. Probes can be read from other manufacturers and the direct transmission of metal loss values, for example, can be fed into Fieldwatch for improved monitoring and analysis.
The CorrLog and SandLog Wireless Transmitter systems are based on intrusive sensors that are installed into pipes or vessels through an access fittings system. Access systems are divided into low pressure systems, such as retractable probes often used in refineries or chemical plants, and high pressure subsea systems, where the Roxar ROV Retrieval System is recommended. The Roxar CorrLog + SandLog wireless transmitters are certified by ATEX and other standards bodies.
The operating principles of the sand probe are based on the Electrical Resistance (ER) corrosion probe technique which relies on the erosive effects of sand particles on thin non-corrosive elements mounted on a probe inserted into the pipe. The Roxar CorrLog Wireless corrosion transmitter is based on the CorrLog instrument.
Emerson Process Management
- Edited by Chris Vavra, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.