Wind turbine at manufacturing plant has hydraulic tip-up tower

Wago Corporation installed a Renewegy VP-20 Wind Turbine capable of generating 20 kW for its Wisconsin headquarters. Hydraulics raise and lower the tower; Wago components are used.

09/21/2011


Tip-up wind turbines installed at Wago's Wisconsin headquarters generate 20 kW. Courtesy: WagoWago Corporation installed a Renewegy small-scale, commercial-grade VP-20 Wind Turbine at its Germantown, Wis., headquarters. Capable of generating 20 kW for Wago's engineering, manufacturing, and sales hub, the VP-20 installation also uses Wago 787 Series power supplies, 756 Series cables and connectors, 288 Series fuse blocks, and backup capacitor module. 

The 30-meter-tall turbine features a monopole tip-down tower with an innovative tip-up function, which essentially raises itself. This replaces large cranes and heavy-duty equipment for install/maintenance with the tip-up hydraulic cylinder system. Within 8-10 minutes, the tower and turbine are raised or lowered. Within just 25 minutes, the VP-20 at the Wago site was raised, spinning at 600+ rpm, and generating power.

Wago Corporation commissioned a Renewegy 20 kW VP-20 small-scale, commercial-grade wind turbine at its Germantown, Wis., headquarters; mock-up image shows position on left. Courtesy: Wago

Key to power generation for the VP-20 is Renewegy's segment-exclusive electronic Variable Pitch (VP) feature. Patterned after utility-scale turbines, VP controls pitch for each blade within 1/10th of a degree while pitching at speeds up to 15 degrees/sec. A closed-loop, Active Pitch Servo manages blade speeds in wind conditions ranging from 6.7-55.9 mph. An electric Active Yaw Servo ensures optimum power generation by directing the blades' direction into the wind.

Power supply and signaling reliability are essential for coping with widely varying wind conditions. Renewegy specified Wago's IP67-grade 756 Series cables and connectors for the VP-20's microprocessor-driven control system. The connections are designed to resist dust, water, and mechanical loosening caused by vibrations.

Anchoring the VP-20 is a control cabinet supported by Wago 288 Series Capacitor Back-Up Module and 787 Series Epsitron Pro 24 V dc power supplies. (These units were specified because they feature PowerBoost, which provides twice the current at constant voltage for approximately 4 sec for cold-weather start ups.)

www.renewegy.com

www.wago.us 

Wago Corporation

See a VP-20 video: http://www.renewegy.com/news.html

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.