SEARCH Archives
Loading
Sponsored by:

Weekly merger, acquisition, deal update: December 28

This week Morrissey Goodale tracked one domestic deal, bringing the total year-to-date deal count in the United States to 179, up 3% over the 174 domestic deals tracked through the same period in 2011. Including the U.S., the total global deal count is now 312, down 6% from the 331 global deals tracked through the same period last year.

Source: Morrissey Goodale

12/28/2012


This week Morrissey Goodale tracked one domestic deal, bringing the total year-to-date deal count in the United States to 179, up 3% over the 174 domestic deals tracked through the same period in 2011. Including the U.S., the total global deal count is now 312, down 6% from the 331 global deals tracked through the same period last year.

This week Morrissey Goodale tracked one domestic deal, bringing the total year-to-date deal count in the United States to 179, up 3% over the 174 domestic deals tracked through the same period in 2011. Including the U.S., the total global deal count is no

M&A Transactions

9/18/2012

In an interesting deal closing earlier this year, leading international water and wastewater treatment, environmental engineering and construction services firm MWH Global (Broomfield, CO) added financial consulting capability for water and wastewater clients by acquiring StepWise Utility Advisors (Englewood, CO), a financial management consulting firm specializing in water and wastewater utilities.  StepWise Utility Advisors serves clients throughout the U.S. and Canada and features services that include financial planning and analysis, cost-of-service allocations, rate design, management consulting and utility valuation. Link to details 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.