Switched-mode power supply: wall mounted, single phase, IP20

Siemens Sitop PSU100D switched mode power supply eliminates traditional rail mounting while meeting basic power supply requirements and is cased in aluminum for IP20 protection.

05/15/2012


The single-phase Sitop PSU100D power supplies can be mounted in various positions on the wall, so a mounting rail is not required. Courtesy: SiemensSiemens Industry Inc. introduces the wall-mounted, single-phase, Sitop PSU100D switched-mode power supply. The screw-mounted PSU100D eliminates the need for traditional rail mounting while affordably meeting the basic power supply requirements.

Ideally suited for wall mounting in apparatuses and machines, the PSU100D features a rugged, low-profile, aluminum casing with IP20 degree of protection that requires little space while enhancing mounting flexibility.

A wide temperature range from -10 to 70 C. accommodates a broad range of applications in harsh environmental conditions.

Six fan-free variants provide a regulated supply of 24 V with rated output currents ranging from 2.1 to 6.25 A and 12 V with 3 or 8.33 A. For higher outputs, two devices of the same type can be connected in parallel.

Single-phase connection to almost any public or industrial supply system is possible due  to a wide-range input of 85 to 264 V ac, radio interference class B and certification in accordance with CE and cULus (Underwriters Laboratories certification for Canada and the U.S.).

The output voltage can be set between 22 V and 28 V using potentiometers in the 24 V variants, and between 11 and 14 V in the 12 V variant. A green LED indicates the operating status "Output voltage OK." Electronic short-circuit, overload and overvoltage protection features ensure safety in the event of a fault.

Siemens Industry Inc.

www.siemens.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.