Starter reduces mounting space

Duo Series combination starter from Fuji Electric Corp. of America consists of two components: BM3 series manual motor starters and SC-E series magnetic contactors. Compact, high-performance motor control system conforms to IEC and UL standards and carries the CE mark. System is designed to cut required mounting space in half and reduce the number of wiring steps by 90%, according to Fuji Elect...

Staff

12/01/2006


Motors, drives, motion control

Duo Series combination starter from Fuji Electric Corp. of America consists of two components: BM3 series manual motor starters and SC-E series magnetic contactors. Compact, high-performance motor control system conforms to IEC and UL standards and carries the CE mark. System is designed to cut required mounting space in half and reduce the number of wiring steps by 90%, according to Fuji Electric estimates.

BM3 series manual motor starter integrates the functions of a molded-case circuit breaker and thermal overload relay into a compact unit. Two frame sizes are offered: 32 A and 63 A. BM3 series can be adjusted to match the rated current of the motor and the variety of safety features includes large breaking capacity, trip indicator, and terminals with finger protection. Available accessories include snap-on auxiliary and alarm contact blocks.

SC-E series small to medium magnetic contactors offer finger protection as standard equipment. Compact (55-mm) contactor width is equal to the BM3 series motor series to provide a slim appearance when configured together. Other offerings in the series include 45-mm type with BM3R starters and SC-E series contactors to handle motor circuits to 10 hp at 240 V ac and 20 hp at 480 V ac; and 55-mm type with BM3V starters and SC-E series contactors to handle motor circuits to 20 hp at 240 V ac or 40 hp at 480 V ac.

Duo Series makes available a variety of connection accessories, power supply units, and bus bar covers. Modular wiring system is said to feature a reduction in equipment, efficient wiring, protection against exposure to charged parts, and space-saving design. www.fujielectric.com

Fuji Electric Corp. of America





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.