Sensors, controls improve beer: Less oxygen, better beer

Oxygen in beer reduces shelf life and can affect flavor. Advanced optical measurement and sensor diagnostic technologies minimizes oxygen, simply and dependably.

12/12/2011


Oxygen in the brewing process is monitored because of its importance on the quality, taste and shelf life of the beer. After fermentation, beer is close to being oxygen free and maintaining this very low oxygen level is important for quality assurance. Therefore O2 uptake during the following separation, filtration, storage and filling processes has to be minimized. To reduce the risk of contamination, permanent and precise oxygen monitoring is required.

The InPro6970i has reduced signal drift and faster response time compared to amperometric sensors guarantees maximum accuracy of the oxygen measurement and allow for enhanced process control. Courtesy: Mettler ToledoContinuous measuring of oxygen concentration places high demands on an in-line O2 system. Such equipment must be easy to install and operate, require minimal maintenance and, most importantly, always measure accurately.

Intelligent optical sensor

The InPro 6970i from Mettler-Toledo delivers at low oxygen levels down to 2 ppb. Based on fluorescence quenching technology, it combines high measurement performance with Intelligent Sensor Management (ISM) functionality.

Optical oxygen sensors offer many advantages over amperometric sensors; reduced and easier maintenance, and long term stability resulting in reduced cost of ownership being only two of them. The only consumable, the OptoCap, has a significantly longer lifetime then amperometric membrane bodies and can easily be replaced within a few minutes. No polarization or liquid handling is necessary. Once the sensor is calibrated it is ready to use.

ISM technology adds to these advantages by simplifying maintenance planning and documentation of all sensor data. Using advanced diagnostic tools, the quality of the sensing element and all sensor components are permanently monitored. Early signs of sensor aging or failure are immediately displayed to the user.

With Plug and Measure, the sensor can be connected to an M400 transmitter, and all data, including calibration and information about the sensor history, e.g. the stresses that the sensor has been exposed to, the number of CIP cycles and much more, are transferred to the transmitter. The system becomes ready for use within a few seconds and no complicated configuration or failure prone calibration at the point of use is required.

http://www.mt.com/InPro6970i

http://www.mt.com/InPro6970i 

www.mt.com/ISM 

Mettler Toledo

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

For other Control Engineering fermentation articles, see below.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.