Preconditioned outside air system

Dedicated outdoor air system allows for flexible building design with selectable airflow rates between 1200 to 2000 cfm.

04/15/2016


Dedicated outdoor air system allows for flexible building design with selectable airflow rates between 1200 to 2000 cfm. Courtesy: LGLG's dedicated outdoor air system (DOAS) is designed to combine preconditioned outside air with variable refrigerant flow (VRF) systems to improve indoor air quality. It allows for flexible building design with selectable airflow rates between 1200 to 2000 cfm, space-efficient reheat coils that can reheat without adding extra bulk, and easy integration with building automation systems. DOAS can precondition and reheat spaces with recovered waste heat from other parts of the building. This allows for it to be fully integrated with a modern VRF system and meet energy standards.

LG

www.lg.com/us



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me