Pluggable relays for industrial, commercial applications

Weidmuller’s generation of pluggable relays meet a wide range of industrial switching requirements.

03/30/2011


Weidmuller’s new generation of pluggable relays meet a wide range of industrial switching requirements. The DRM Series relay complements Weidmuller’s proven electromechanical and solid-state relays that are installed in millions of devices worldwide.

The DRM Series relays are ideal for most industrial and commercial applications. They are available in 2 and 4 changeover versions for ac and dc coil input voltages. The relay contacts are made from a heavy electroplated silver alloy that measures 270 microns thick. This precious metal contact surface allows for a wide range of loads, from only a few milliamps up to 10 amps per contact, and ensures added reliability and extended relay life. In addition, DRM Series relays offer full load switching capability over a wide temperature range (-40°C to +60°C) without the need for de-rating. All DRM relays can be used in temperatures up to +80°C with de-rated switching capabilities.

The compact DRM Series relays provide optional features that increase reliability and simplify installation. An integrated LED with a unique color for the ac and dc coils provides clear status indication and quick trouble shooting. Color-coded test levers for mechanical contact operation enable users to simulate switching status, for simplified commissioning and service.

The DIN-rail mountable relay sockets feature high quality screw terminals that accept stripped wire, insulated bootlace ferrules or insulated fork lugs.

All products in Weidmuller’s DRM Seriesare CE and cURus approved and RoHS compliant, for use in industrial applications worldwide.

www.weidmuller.com

Weidmuller

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me