Omega Engineering Universal Remote I/O Modules

HE359 Series Universal Remote I/O Modules provide remote I/O for programmable logic controllers (PLCs). With remote I/O, the application is no longer dependent on controller choice.

02/03/2010


I/O Modules: Product research and advice from Control Engineering subscribers

 

Omega Engineering Universal Remote I/O Modules

Omega Engineering Universal Remote I/O Modules

HE359 Series Universal Remote I/O Modules provide remote I/O for programmable logic controllers (PLCs). Omega Engineering HE359RTD100:
• Connects via 2-wire RS-485 Modbus (RTU or ASCII) to any programmable logic controller (PLC);
• Offers up to 31 I/O modules daisy-chained on one RS-485 link;
• Is DIN-rail mountable;
• Has optical isolation;
• Includes response time suitable for most analog applications;
• Has cost effective addition per point;
• Fits in the smallest panels: 17.5 x 100 x 120 mm (0.69-in. x 3.94-in. x 4.72-in.); and
• Has 12 I/O modules from which to choose, including dc in, relay out, analog in, analog out, RTD, thermocouple.

Remote I/O, or distributed I/O, offers several advantages over the traditional local I/O found on a programmable logic controller (PLC).

First, it allows locating the I/O modules close to the process that is being monitored or controlled. This greatly improves noise immunity, as the weak sensor signals are converted to digital signals before being transmitted long distances through a noisy plant environment. Omega universal remote I/O modules use a simple 2-wire RS-485 link using Modbus RTU/ASCII protocol, which is supported by most programmable logic controllers.

A second advantage is that remote I/O greatly reduces the wiring at the main control panel, saving time and money when repairs and upgrades are necessary. Adding additional sensors and control signals is as easy as connecting to the already installed RS-485 link and modifying the PLC program to use the new I/O connection.

In addition, remote I/O allows expansion of a process control system beyond the local I/O capabilities of your PLC. You can add thermocouple, RTD, pressure, and flow sensors to a PLC that doesn't support these types of inputs. With remote I/O, your process application is no longer dependent on your controller choice. www.omega.com/ppt/pptsc.asp?ref=HE359&nav=AUTW01

Also see:

- New series of NEMA motor starters;

- Electronic pressure switch includes LED display ;

- 5 tips for monitoring temperature wirelessly .

- Edited by Mark T. Hoske, editor in chief, Control Engineering , www.controleng.com.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me