NIWeek: New Ethernet data acquisition platform

New National Instruments CompactDAQ System is said to provide high-speed, distributed sensor measurements. Chassis holds eight I/O modules for 256 channels of electrical, physical, mechanical or acoustic signals in 25 cm by 9 cm by 9 cm, rugged form factor, using standard Gigabit Ethernet infrastructure. More than 50 modules are available.

08/04/2010


New National Instruments CompactDAQ SystemNational Instruments (Nasdaq: NATI) announced the new Ethernet-based NI CompactDAQ modular data acquisition system, at its NIWeek meeting on Aug. 3. The DAQ system combines the ease of use and low cost of a data logger with the performance and flexibility of modular instrumentation, the company said. The new NI cDAQ-9188 chassis is designed to hold eight I/O modules for measuring up to 256 channels of electrical, physical, mechanical or acoustic signals in a small (25 x 9 x 9 cm), rugged form factor. With more than 50 I/O modules to choose from, engineers and scientists can build remote or distributed, high-speed measurement systems using standard Gigabit Ethernet infrastructure. In addition, NI CompactDAQ simplifies initial setup with zero configuration networking technology and a built-in, Web-based configuration and monitoring utility.

“We chose NI CompactDAQ because of the flexibility offered by a diverse set of I/O modules and the scalability of Ethernet infrastructure,” said Randy Recob, senior test engineer at Sub-Zero Inc. “The flexibility of Ethernet allows us to more easily standardize our test systems by eliminating many of the physical constraints required by more traditional PC interfaces.” Recob said reasons for use include  measurement accuracy, system stability, and ease of use.

The NI product uses patented NI Signal Streaming technology to deliver high-bandwidth data over Ethernet to a host computer. The streaming provides the ability to maintain bidirectional analog and digital waveform over a TCP/IP connection. With NI-STC3 timing and synchronization technology, each chassis also can manage up to seven hardware-timed I/O tasks at different sample rates, including analog I/O, digital I/O and counter/timer operations. The chassis operate in a temperature range of -20 to 55 degrees Celsius and can withstand up to 30 g shock and 3 g vibration. Specifications are suitable for test applications on the benchtop, in the field or on the production line, the company said.

In addition to the Ethernet chassis, the NI CompactDAQ platform includes a four- and an eight-slot USB chassis and NI C Series I/O modules. NI offers more than 50 C Series modules for NI CompactDAQ systems, each is hot-swappable and auto-detectable for simplified setup. C Series modules offer integrated signal conditioning and multiple connectivity options to create custom, mixed-measurement systems specific to the needs of an application. One analog input module can,acquire up to four channels of simultaneous 1 MS/s voltage inputs for measuring high-speed signals, such as ballistic pressure or ultrasonic transducers.

NI-DAQmx driver software, which is included with NI CompactDAQ, goes beyond a basic device driver to deliver increased productivity and performance. With NI-DAQmx, engineers and scientists can log data for simple experiments or develop a complete test system in NI LabVIEW, NI LabWindows/CVI, ANSI C/C++ or Microsoft Visual Studio .NET. A consistent API means that an application developed for an NI CompactDAQ USB chassis will work with an NI CompactDAQ Ethernet chassis without software changes.

NI LabVIEW graphical programming makes it possible for engineers and scientists to develop sophisticated measurement, test and control systems using intuitive graphical icons and wires that resemble a flowchart. The multiple timing engines featured on NI CompactDAQ chassis complement the multicore optimizations in LabVIEW to make programming multiple measurement tasks in parallel easy. The software integrates with thousands of other hardware devices and provides hundreds of built-in libraries for advanced analysis and data visualization.

Learn more about NI CompactDAQ Ethernet data acquisition system at www.ni.com/new_compactdaq.

Sub-Zero offers dual refrigeration designs, a technology said to preserve food freshness longer. Each unit is tested for at least five hours, the company said. www.subzero.com

Also read:

NIWeek: NI LabVIEW 2010 optimizes compiler for faster code execution

NIWeek 2010: Explore technologies, gain competitive advantages

National Instruments: 3 distributed I/O hardware platforms

- Edited by Mark T. Hoske, Control Engineering, www.controleng.com.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.